A-3
Cisco Content Delivery Engine 205/220/250/280/285/420/460/475 Hardware Installation Guide
Appendix A Technical Specifications
CDE280 Specifications
CDE280 Specifications
lists the technical specifications and management information for the CDE280.
Operating Temperature
50 to 95°F (10 to 35°C)
Nonoperating Temperature
–104 to 158°F (–40 to 70°C)
Operating Altitude
0 to 4000 m
Dimensions (H x W x D)
3.5 x 17.2 x 25.5 in. (8.9 x 43.7 x 64.8 cm)
Weight (fully configured)
52 lb (23.58 kg)
Approvals: Safety
UL/CSA 60950-1
Approvals: EMC
FCC Part 15 (CFR 47) Class A
Table A-2
CDE220 Specifications
Rack Units
2
Table A-3
CDE280 Specifications
Rack Units
2
Power
90 to 264 VAC (self-ranging, 180 to 264 VAC nominal)
Power Rating
1200 W peak
DC Power Rating
930W peak
AC Electrical Input
11 Amps maximum at 100 VAC
7 Amps maximum at 208 VAC
DC Electrical Input
–48 to –60 VDC nominal
(self-ranging, –40 to –72 VDC)
DC Connector Type
Amphenol
Power Connector Cables
Wire cable gauge 12 AWG
Operating Relative Humidity
10 to 90%, non-condensing at 82° F (28° C)
Nonoperating Relative
Humidity
5 to 93% at 82° F (28° C)
Operating Temperature
41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of
altitude above sea level.
Nonoperating Temperature
–40 to 149°F (–40 to 65°C)
(when the server is in storage or is transported)
Operating Altitude
0 to 10,000 feet
Dimensions (H x W x D)
W x D (Including handles)
3.43 x 17.65 x 29.0 in. (8.7 x 44.8 x 73.80 cm)
18.96 x 30.18 in. (48.2 x 76.6 cm)
Weight (fully configured)
62.7 lb. (28.4 Kg)
Front Clearance
3 in. (76 mm)