4-25
Cisco Content Delivery Engine 205/220/250/280/285/420/460/475 Hardware Installation Guide
Chapter 4 Installing the VDS Internet Streamer Software and Initially Configuring a CDE
Re manufacturing a CDE
Step 6
After the reload, run the following command to set up the drives.
#disk policy apply
#
The device changes to CDE280-2S10. To check the device that you are currently working on, run the
following command:
#show inventory
The system displays the following:
PID: CDE280-2S10 VID: 01 SN: FCH1834V3AU
Replacing CDE280 chassis
CDE280 has 6 sub-prototypes, and the spare lite CDE280 chassis can be manufactured into anyone of
them. This section will explain how to manufacture a spare lite CDE280 chassis into a CDE280
sub-prototype.
Requirement
•
A CDE280 spare lite chassis
•
Corresponding drives
lists the CDE280 sub-prototype and its external drives
After this process, drives loses its data.
For example, to manufacture a spare lite CDE280 chassis into CDE280-2S5, do the following:
Step 1
Configure the CIMC and remote presence.
For more information, see
Step 2
Push 24 x 240G drives into the front panel of the chassis.
According to the previous table, CDE280-2S5 should have 24 x 240G drives.
Step 3
Power on the device.
Table 4-6
CDE280 sun-prototype and its external drives
CDE280 Variation
External Drives
2H1
600G HDD x 1
2H13
600G HDD x 24
2H26
1200G HDD x 24
2S5
240G SSD x 24
2S10
480G SSD x 24
2S21
960G SSD X 24