DC Electrical Input
DC input voltage range: –36VDC to –75VDC
See the
“If DC Power Supplies Are Installed” section on page 2-12
DC Connector Type
Molex
Power Connector Cables
Wire cable gauge 8 AWG
Operating Relative Humidity
8 to 90% (noncondensing)
Nonoperating Relative
Humidity
5 to 95% (noncondensing) at temperatures of 73°F to 104°F (23°C
to 40°C)
Operating Temperature
50° to 95°F (10 to 35°C)
Nonoperating Temperature
–104° to 158°F (–40°to 70°C)
Operating Altitude
0 to 4000 m
Dimensions (H x W x D)
3.5 x 17.2 x 25.5 in. (8.9 x 43.7 x 64.8 cm)
Weight (fully configured)
52 lb (23.58 kg)
Approvals: Safety
UL/CSA 60950-1
Approvals: EMC
FCC Part 15 (CFR 47) Class A
Table A-1
CDE205 Specifications
Rack Units
2
Table A-2
CDE220 Specifications
Rack Units
2
Power
100 to 240 VAC or –48 VDC redundant power supplies included in
all models
Power Rating
800 W peak
DC Power Rating
710 W peak
AC Electrical Input
•
AC input voltage low range—Minimum: 100 VAC,
Maximum: 127 VAC
•
AC input voltage high range—Minimum: 200 VAC,
Maximum: 240 VAC
See the
“If AC Power Supplies Are Installed” section on page 2-9
DC Electrical Input
DC input voltage range: –36VDC to –75VDC
See the
“If DC Power Supplies Are Installed” section on page 2-12
DC Connector Type
Molex
Power Connector Cables
Wire cable gauge 8 AWG
Operating Relative Humidity
8 to 90% (non-condensing)
Nonoperating Relative
Humidity
5 to 95% (non-condensing) at temperatures of 73°F to 104°F (23°C
to 40°C)