Cisco Content Delivery Engine 
205/220/250/280/285/420/460/475 Hardware 
Installation Guide

October 05, 2018

Содержание CDE 205

Страница 1: ...as more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco website at www cisco com go offices Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide October 05 2018 ...

Страница 2: ...NGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES Cisco and the...

Страница 3: ...s 1 1 Cisco VDS Internet Streamer Overview 1 1 Cisco VDS TV Overview 1 3 Cisco CDA Visual Quality Experience Application Overview 1 5 VQE Major Software Components 1 7 OMD Overview 1 7 Hardware Features 1 7 CDE Configurations 1 15 CDE205 Hardware Overview 1 16 CDE220 Hardware Overview 1 17 CDE250 Hardware Overview 1 18 CDE250 Connectivity 1 20 CDE280 Hardware Overview 1 21 CDE285 Hardware Overview...

Страница 4: ... F 1 34 CDE250 2A4 1 35 CDE250 2A2 1 35 CDE250 2G3 1 36 CDE250 2M0 1 37 CDE250 2S5 1 37 CDE250 2S6 1 38 CDE250 2S8 1 39 CDE250 2S9 1 39 CDE250 2S10 1 40 CDE250 2V0 1 41 CDE280 1 41 CDE285 S 1 42 CDE285 L 1 43 CDE420 4A C 1 44 CDE420 4A F 1 44 CDE420 4G C 1 45 CDE420 4G F 1 45 CDE460 1 46 CDE460 4R1 1 47 CDE460 4R3 1 48 CDE475 1 49 Front Panel Control Buttons and LEDs 1 50 Front Panel Control Panel...

Страница 5: ... R 3 Installing the Content Delivery Engines 3 1 Tools and Parts Required 3 1 Unpacking the Box 3 1 Inspecting for Damage 3 2 Installing the CDEs 3 2 Reviewing Rack Installation Safety Guidelines 3 3 Preparing the CDEs for Rack Installation 3 3 Replacing External Storage Drives 3 3 Replacing a CDE280 Drive 3 8 Replacing a Power Supply 3 9 Replacing a CDE280 Power Supply 3 12 Device Connection Test...

Страница 6: ...Configuring a CDE 4 1 Launching a New CDE for the First Time 4 1 Launching a CDE280 for the First Time 4 3 Configure the CIMC IP 4 3 Configure Remote Presence 4 5 Connect to the Console 4 7 Configure VDS IS Software 4 7 Configuring SNMP 4 8 Re manufacturing a CDE 4 14 Before You Begin 4 14 Installing a CDE 4 15 Re manufacturing and Installing CDE280 4 17 CDE280 Model Migration 4 23 Replacing CDE28...

Страница 7: ... P E N D I X A Technical Specifications A 1 CDE205 Specifications A 1 CDE220 Specifications A 2 CDE280 Specifications A 3 CDE285 Specifications A 4 CDE420 Specifications A 5 CDE460 Specifications A 6 CDE475 Specifications A 7 CDE Management A 7 CDE Heat Rate Load A 8 A P P E N D I X B Connector Pin Assignments B 1 Serial Console Interface Connector Pin Assignments B 1 Serial Port Connector B 2 KVM...

Страница 8: ...ubleshooting Scenarios Host Does not Boot D 7 Common Troubleshooting Scenarios BMC D 7 Accessing CIMC on CDE280 Service Engine D 7 Connecting to the console D 9 A P P E N D I X E Configuring VDS IS CDE280 Disks E 1 Changing the Disk Status Using KVM Console E 1 Changing Drive Status Using CIMC Console E 9 A P P E N D I X F VDS IS and VQE CDE280 and CDE285 CIMC BIOS Firmware F 1 VDS IS and VQE CDE ...

Страница 9: ...g Documentation and Submitting a Service Request page xix Document Revision History Table 1 records technical changes to this document Table 1 Document Revision History Document Version Date Change Summary October 05 2018 Added CDE475 support for VDS TV January 31 2018 CDE470 is not supported in VDS TV December 09 2016 Added CDE285 support for OMD Open Media Distribution September 29 2016 Added CD...

Страница 10: ... model 2V0 for Visual Quality Experience VQE and the Very Dense TV and IS Flash Streamers CDE250 models 2S8 2S9 and 2S10 OL 16887 07 October 31 2011 Added Dense IS Streamer CDE250 model 2M0 Updated baud information for the TV CDS installation and the storage device removal procedure OL 16887 05 March 31 2010 Added Dense Cisco Internet Streamer CDE220 model 2S3I OL 16887 04 October 30 2009 Added Fl...

Страница 11: ...rmation to install the Videoscape Distribution Suite VDS hardware components Chapter 4 Installing the VDS Internet Streamer Software and Initially Configuring a CDE Describes the initial installation of the VDS IS software application onto the CDEs and the initial configuration of the CDEs using the Content Delivery System Manager CDSM Chapter 5 Installing the VDS TV Software and Initially Configu...

Страница 12: ...oftware Configuration Guide Cisco Internet Streamer CDS Command Reference Cisco Internet Streamer CDS Alarms and Error Messages Guide Cisco Internet Streamer CDS Quick Start Guide Cisco Internet Streamer CDS API Guide Release Notes for Cisco Internet Streamer CDS Cisco Internet Streamer CDS Installation Guide Cisco TV VDS ISA Configuration Guide Cisco TV VDS RTSP Configuration Guide Cisco TV VDS A...

Страница 13: ...isco com en US products ps10493 prod_installation_guides_list html The OMD related documents are listed as follows Cisco UCS C240 M4 High Density Rack Server Small Form Factor Disk Drive Model Cisco UCS C240 M4 High Density Rack Server Large Form Factor Disk Drive Model Cisco UCS C240 M4 Server Installation and Service Guide Conventions Note Means reader take note Notes contain helpful suggestions...

Страница 14: ...huwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd wilt raadplegen BEWAAR DEZE INSTRUCTIES Varoitus TÄRKEITÄ TURVALLISUUSOHJEITA Tämä varoitusmerkki merkitsee vaaraa Tilanne voi aiheuttaa ruumiillisia vammoja Ennen kuin käsittelet laitteistoa huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitu...

Страница 15: ...yr fare Du er i en situasjon som kan føre til skade på person Før du begynner å arbeide med noe av utstyret må du være oppmerksom på farene forbundet med elektriske kretser og kjenne til standardprosedyrer for å forhindre ulykker Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten TA VARE PÅ DISSE INSTRUKSJONENE Aviso ...

Страница 16: ...ner dig i en situation som kan leda till personskada Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning SPARA DESSA ANVISNINGAR ...

Страница 17: ...da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo GUARDE ESTAS INSTRUÇÕES Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare Du befinder dig i en situation med risiko for legemesbeskadigelse Før du begynder arbejde på udstyr skal du være opmærksom på de involverede risici der er ved elek...

Страница 18: ...xviii Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide ...

Страница 19: ... the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at the following URL http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds...

Страница 20: ...xx Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide ...

Страница 21: ...ning Content Delivery Applications CDAs that collaborate with each other to deliver multiformat content to a variety of client devices The client devices supported are personal computers and Wi Fi enabled mobile devices The VDS IS supports a variety of functions to accelerate the distribution of content within the content delivery network The VDS IS offers an end to end solution for service provid...

Страница 22: ...f configuration parameters that dictate how content is ingested and distributed and what content is delivered to the client devices Some of the primary delivery service definition parameters are as follows Origin server Service routing domain name Service Engines participating in the delivery service Service Engine designated as the Content Acquirer The Content Acquirer is active on only one Servi...

Страница 23: ...t The VDS TV interoperates with electronic program guides EPGs set top boxes STBs and back office applications offering an end to end solution for video delivery systems The Cisco VDS TV functionality can be separated into four areas Ingest Storage Streaming Management Service Engine Content Acquirer Service Engine Internet Streamer CDSM Origin servers Content provider c o n t e n t metadata metad...

Страница 24: ... catching Sometimes there is some overlap of functionality between the BMS and the AMS Figure 1 2 High Level System View of VDS TV The Cisco VDS TV solution has four major elements Table 1 2 CDA Mapping to Functionality and TV CDSM CDA Name Functionality CDSM Device Name Vault Ingest and storage Vault TV Streamer Content caching personalization and streaming to STBs Streamer TV PlayOut Multicast o...

Страница 25: ...rove the quality of IPTV services and viewing experiences of the subscriber VQE is part of a Cisco end to end solution that builds video awareness into the network infrastructure VQE technology is intended for wireline operators who offer managed broadcast multicast IPTV services using xDSL IPTV subscribers expect high video quality Because many subscribers are migrating from existing analog or di...

Страница 26: ...ator such as the Cisco Digital Content Manager DCM is required The FEC stream generator shown in Figure 1 4 is often located in the headend and sends application layer FEC packets RTP encapsulation is a prerequisite for FEC The FEC stream generator which is connected to the real time encoders subscribes to video channels from the headend and encodes FEC for each channel It is responsible for origi...

Страница 27: ... runs on a Linux based CDE250 and CDE280 appliance located in the intelligent edge of the service provider s network For Unicast Retransmission and RCC the VQE S caches primary video packets from an encoder or other headend device For Unicast Retransmission working with the VQE C the VQE S monitors the subscriber s reception of video packets and uses its cached video data to service Unicast Retran...

Страница 28: ...res The CDE250 model 2S5 2S6 2S8 2S9 and 2S10 are used with both VDS IS and VDS TV The CDE250 model 2V0 is used with VQE The CDE280 model is used with VQE The following CDE is used only for OMD CDE285 Figure 1 5 shows the CDE205 and CDE220 Figure 1 6 shows the CDE250 Figure 1 7 shows the CDE420 and CDE460 Figure 1 5 CDE205 and CDE220 Figure 1 6 CDE250 254337 ...

Страница 29: ...e CDE285 L see Cisco UCS C240 M4 High Density Rack Server Large Form Factor Disk Drive Model Figure 1 8 is the rear view of the CDE205 and CDE220 showing the location of the power supplies connectors and slots Figure 1 8 CDE205 and CDE220 Rear View 1 Power connectors the CDE205 only has one 5 Parallel port not supported 2 PCI expansion slots 6 Serial console interface 3 Interfaces eth0 on left eth...

Страница 30: ... View 1 1 Power connectors 12 USB port 5 2 Keyboard 13 GigabitEthernet 1 1 eth1 on left 3 Mouse 14 GigabitEthernet 1 0 eth0 on right 4 Com port 15 Side Surround 5 VGA interface 16 Back Surround 6 USB port 0 17 CE LFE 7 USB port 1 18 Microphone In 8 IPMI Dedicated LAN X8DAH F only 19 Front 9 USB port 2 20 Line In 10 USB port 3 21 PCI Expansion Slots1 1 Slots are shown in descending order left to ri...

Страница 31: ...1 is the rear view of the CDE S and CDE285 L showing the location of the power supplies connectors and slots 1 TenGigabit Ethernet Port 6 Serial connector RJ 45 2 TenGigabit Ethernet Port 7 Two embedded on the motherboard Intel i350 GbE Ethernet controller ports GigabitEthernet 1 0 eth0 on left and GigabitEthernet 1 1 eth1 on right 3 Power Supplies 8 VGA video port DB 15 connector 4 USB Ports 9 Re...

Страница 32: ...nGigabit Ethernet Port 6 Serial connector RJ 45 2 TenGigabit Ethernet Port 7 Two embedded on the motherboard Intel i350 GbE Ethernet controller ports GigabitEthernet 1 0 eth0 on left and GigabitEthernet 1 1 eth1 on right 3 Power Supplies 8 VGA video port DB 15 connector 4 USB Ports 9 Rear Unit Identification button LED 5 Gbps dedicated management port 10 Grounding lug holes for DC power supplies ...

Страница 33: ...1 12 is the rear view of the CDE420 showing the location of the power supplies connectors and slots Figure 1 12 CDE420 Rear View 1 Power connectors 6 Parallel port not supported 2 Fans 7 Serial console interface 3 PCI expansion slots 8 USB ports 4 Interfaces eth0 on left eth1 on right 9 Mouse and keyboard connectors 5 VGA Interface 204343 1 1 2 3 4 5 6 7 7 6 5 4 9 8 2 3 ...

Страница 34: ...upplies connectors and slots Figure 1 13 CDE460 Rear View 1 Power connectors 9 Mouse and keyboard connector 2 Fans 10 1 Gigabit Ethernet management port eth1 3 Serial port 11 1 Gigabit Ethernet management port eth0 4 IPMI port 12 USB port 5 USB port 13 USB port 6 1 Gigabit Ethernet management port eth2 14 USB port 7 1 Gigabit Ethernet management port eth3 15 12 storage drives 8 PCI expansion slots...

Страница 35: ...20 TV 2D1 F CDE220 K9 CB 16 12A500 2QTX CDE220 IS 2G2 C CDE220 K9 CB 16 12A500 4DSX CDE220 IS 2G2 F CDE220 K9 CB 16 4F160 1QTX CDE220 TV 2S1 C CDE220 K9 CB 16 4F160 2DSX CDE220 TV 2S1 F CDE220 K9 CB 32 12F160 3QTX CDE220 TV 2S3 C CDE220 K9 CB 32 12F160 4DSX CDE220 TV 2S3 F CDE220 K9 CB 32 12FI160 3QTX CDE220 IS 2S3I C CDE220 K9 CB 32 12FI160 4DSX CDE220 IS 2S3I F CDE250 K9 CB 48 HVY 2WPL SB 24S1T ...

Страница 36: ... CDE280 TV 2U1 CDE280 K9 SB CDE280 2U2 CDE280 TV 2U2 CDE280 K9 SB CDE280 2U3 CDE280 TV 2U3 CDE280 K9 SB CDE280 2V0 CDE280 VQE 2V0 CDE280 K9 SB CDE280 2U4 CDE280 TV 2U4 CDE285 S SB CDE285 2S10 CDE285 S OMD 2S10 CDE285 S SB CDE285 2H26 CDE285 S OMD 2H26 CDE285 S SB CDE285 2H40 CDE285 S OMD 2H40 CDE285 L SB CDE285 2H90 CDE285 L OMD 2H90 CDE420 K9 CB 32 24A1T 2QTX CDE420 TV 4A C CDE420 K9 CB 32 24A1T ...

Страница 37: ...n CDE PID Drives RAM Product Name Hardware Support First Introduced Ports CDE205 CDE205 2 500TX K9 3 500 GB SATA 8 GB Entry level IS streamer CDS IS Manager Service Router Content Acquirer or Proximity Engine VDS IS 3 0 2 Gigabit Ethernet ports Table 1 5 Supported CDE220 Configurations CDE PID Drives RAM Product Name Hardware Support First Introduced NIC CDE220 2A C CB 32 12A1T 2QTX 12 1 TB SATA 3...

Страница 38: ...ions CDE220 2G2 C CB 16 12A500 2QTX 12 500 GB SATA 16 GB Dense IS Streamer Service Router or Content Acquirer VDS IS 3 0 2 Quad 8 GE Copper CDE220 2G2 F CB 16 12A500 4DSX 12 500 GB SATA 16 GB Dense IS Streamer Service Router or Content Acquirer VDS IS 3 0 4 Dual 8 GE Fiber CDE220 2S1 C1 CB 16 4F160 1QTX 4 160 GB SSD 16 GB Entry level TV Streamer CDS TV 3 0 1 Quad 4 GE Copper CDE220 2S1 F1 CB 16 4F...

Страница 39: ...able SFP Module 4 1GE Copper Ports CDE250 2M0 CB 48 XVR 2WPL SB 16A500 16 500GB SATA HDD 48 GB Dense IS Streamer VDS IS 3 0 2 Dual 10GE Ports Copper or Fiber by removable SFP Module 1 Quad 4GE Copper Port CDE250 2S5 CB 48 HVY 2WPL SB 12F160 12 160 GB 2 5 Flash SSD 48 GB Dense TV Streamer Dense IS Streamer CDS TV 3 0 VDS IS 3 2 1 4 10GE Ports Copper or Fiber by removable SFP Module 4 1GE Copper Por...

Страница 40: ...y shared by all 16 ports within the line card Do not connect four CDE interfaces to the same group to eliminate sharing the same 10 GE fabric The total CDE s aggregate bandwidth is limited to 10 GE if all four 10 GE ports are connected to the same group Figure 1 14 shows the port group mapping for a 4 port performance mode on the front panel of the 16 port 10 GE module WS X6716 10GE Figure 1 14 WS...

Страница 41: ...lications The CDE280 is a fully optimized solution on the Cisco Unified Computing SystemTM Cisco UCS server platform The CDE280 ships with the following components installed 2 Intel Xeon 3 20 GHz E5 2667 v3 series processor 2 onboard copper Gigabit Ethernet ports 2 hot swappable redundant power supplies AC power supplies 1200 W AC each DC power supplies 930W 48V DC Common Power Supply 6x16 GB RDIM...

Страница 42: ...ctor Disk Drive Model Note For more details about the CDE285 L hardware overview see Cisco UCS C240 M4 High Density Rack Server Large Form Factor Disk Drive Model CDE280 2H1 CDE280 K9 SB CDE280 2H1 1 x 600 SAS 96GB VDS IS 4 1 1 8 10GE Ports SFP CDE280 2H13 CDE280 K9 SB CDE280 2H13 24 x 600 SAS 96GB VDS IS 4 1 1 8 10GE Ports SFP CDE280 2H26 CDE280 K9 SB CDE280 2H26 24 x 1200 SAS 96GB VDS IS 4 1 1 8...

Страница 43: ...d to bay expanders designed to slide into the front of the CDE420 chassis on 420 4A C and 420 4A F models 24 450 GB 3 5 inch SAS drives mounted to bay expanders designed to slide into the front of the CDE420 chassis on 420 4G C and 4G F models Note External drives and bay expanders are shipped separately and are not installed in the CDEs Table 1 9 shows the supported CDE420 configurations Table 1 ...

Страница 44: ... to bay expanders designed to slide into the CDE460 chassis 24 in the front of the chassis and 12 in the rear 36 4 TB SAS drive is mounted to bay expanders designed to slide into the CDE460 chassis model used is 4R3 Note External drives and bay expanders are shipped separately and are not installed in the CDEs Table 1 10 shows the supported CDE460 configuration CDE420 4G C CB 32 24S450 3QTX 24 450...

Страница 45: ...into the CDE475 chassis 24 in the front of the chassis and 12 in the rear Note External drives and bay expanders are shipped separately and are not installed in the CDEs Table 1 11 shows the supported CDE475 configuration CDE460 CB 128 2WPL SB36S3T 36 3 TB SATA 128 GB Recorder CDS TV 3 0 4 10GE Ports Copper or Fiber by removable SFP Module 4 1GE Copper Ports CDE460 4R3 CB 128 HVY 2WPL SB 36S4T 4 T...

Страница 46: ... Figure 1 15 is a front view of the CDE205 showing the location of the storage drives The CDE205 has no expansion cards Figure 1 15 CDE205 Drives CDE220 2A C Figure 1 16 is a front view of the CDE220 2A copper and fiber models showing the location of the storage drives Table 1 12 lists the CDE220 2A C PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location o...

Страница 47: ... of the storage drives Table 1 14 lists the CDE220 2C1 C PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Figure 1 17 CDE220 2C1 F C Drives 6 7 Table 1 12 CDE220 2A C PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom Table 1 13 CDE220 2A F PCI Expansion Cards PCI Expansion Slot Number ...

Страница 48: ... front view of the CDE220 2C2 fiber and copper models showing the location of the storage drives Table 1 16 lists the CDE220 2C2 C PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Figure 1 18 CDE220 2C2 F C Drives 3 4 5 6 77 Table 1 14 CDE220 2C1 C PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name t...

Страница 49: ...he location of the storage drives Table 1 18 lists the CDE220 2D1 C PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Figure 1 19 CDE220 2D1 F C Drives Table 1 16 CDE220 2C2 C PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC quad copper eth6 eth7 eth8 eth9 3 NIC quad copper eth...

Страница 50: ...2G2 copper and fiber models showing the location of the storage drives Table 1 20 and Table 1 21 list the CDE220 2G2 C PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Figure 1 20 CDE220 2G2 F C Drives Table 1 18 CDE220 2D1 C PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC qu...

Страница 51: ...g the location of the storage drives Table 1 22 lists the CDE220 2G2 F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Table 1 20 CDE220 2G2 C PCI Expansion Cards for Release 2 4 x and Later PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC quad copper 7 0 8 0 9 0 10 0 3 NIC quad copper 3 0 4 0 5...

Страница 52: ...0 2S1 F C Drives CDE220 2S1 F Figure 1 21 is a front view of the CDE220 2S1 copper and fiber models showing the location of the storage drives Table 1 24 lists the CDE220 2S1 F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots 4 5 NIC dual fiber 7 0 8 0 6 NIC dual fiber 9 0 10 0 7 Table 1 22 CDE220 2G2 F PCI Expansion Cards P...

Страница 53: ...DE220 2S3 copper and fiber models showing the location of the storage drives Table 1 26 lists the CDE220 2S3 F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Table 1 24 CDE220 2S1 F Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC dual fiber eth4 eth5 3 NIC dual fiber eth2 eth3 ...

Страница 54: ...and fiber models showing the location of the storage drives Table 1 28 lists the CDE220 2S3I F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 8 to see the location of the PCI expansion slots Table 1 26 CDE220 2S3 F Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC dual fiber eth4 eth5 3 NIC dual fiber eth2 eth3 4 5 NIC dual fib...

Страница 55: ...wing the location of the storage drives Table 1 30 lists the CDE250 2A2 PCI expansion cards and their corresponding PCI slot numbers see Figure 1 9 to see the location of the PCI expansion slots Table 1 28 CDE220 2S3I F Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC dual fiber 5 0 6 0 3 NIC dual fiber 3 0 4 0 4 5 NIC dual fiber 7 0 8 0 6 NIC dual fibe...

Страница 56: ...on of the PCI expansion slots Figure 1 26 CDE250 2G3 Drives 382852 RESET 1 2 3 4 5 6 7 8 9 10 11 12 Table 1 30 CDE250 2A2 PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC dual 10GE fiber eth6 eth7 3 4 5 6 NIC dual 10GE fiber eth8 eth9 7 NIC quad copper eth2 eth3 eth4 eth5 RESET 254339 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Ta...

Страница 57: ... Figure 1 28 is a front view of the CDE250 2S5 showing the location of the storage drives Table 1 33 lists the CDE250 2S5 PCI expansion cards and their corresponding PCI slot numbers see Figure 1 9 to see the location of the PCI expansion slots Note If this CDE is in an IS system the storage drive numbering is from 0 to 25 Figure 1 28 CDE250 2S5 Drives RESET 285399 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Страница 58: ... Figure 1 29 CDE250 2S6 Drives Table 1 33 CDE250 2S5 PCI Expansion Cards PCI Expansion Slot Number Expansion Card VDS IS Interface Name top to bottom VDS TV Interface Name top to bottom 1 2 NIC dual 10GE fiber 1 0 2 0 eth6 eth7 3 4 5 6 NIC dual 10GE fiber 3 0 4 0 eth8 eth9 7 NIC quad copper 3 0 4 0 5 0 6 0 eth2 eth3 eth4 eth5 RESET 254339 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 59: ...is a front view of the CDE250 2S9 showing the location of the storage drives Table 1 36 lists the CDE250 2S9 PCI expansion cards and their corresponding PCI slot numbers see Figure 1 9 to see the location of the PCI expansion slots Note If this CDE is in an IS system the storage drive numbering is from 0 to 12 Figure 1 31 CDE250 2S9 Drives RESET 254339 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 ...

Страница 60: ... Figure 1 32 CDE250 2S10 Drives Table 1 36 CDE250 2S9 PCI Expansion Cards PCI Expansion Slot Number Expansion Card VDS IS Interface Name top to bottom VDS TV Interface Name top to bottom 1 2 NIC dual 10GE fiber 1 0 2 0 eth6 eth7 3 4 5 6 NIC dual 10GE fiber 3 0 4 0 eth8 eth9 7 NIC quad copper 3 0 4 0 5 0 6 0 eth2 eth3 eth4 eth5 RESET 254339 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2...

Страница 61: ...s For the procedure on installing VQE software on the CDE250 2V0 see the Installing VQE Release 3 6 Software section of the Release Notes for Cisco CDA Visual Quality Experience Application Release 3 6 CDE280 Figure 1 34 is a front view of the 24 drive CDE280 showing the location of the storage drive Table 1 39 lists the CDE280 expansion cards and their corresponding PCI slot numbers see Figure 1 ...

Страница 62: ...I Expansion Slot Number Expansion Card1 1 These mappings are valid only when the CIMC NIC mode is dedicated default setting VDS IS Interface Name 1 NIC dual 10GE fiber TenGigabitEthernet 1 0 eth2 Left and TenGigabitEthernet 1 1 eth3 Right 2 NIC dual 10GE fiber TenGigabitEthernet 2 0 eth4 Left and TenGigabitEthernet 2 1 eth5 Right 3 Blank 4 NIC dual 10GE fiber TenGigabitEthernet 3 0 eth6 Left and T...

Страница 63: ... Density Rack Server Large Form Factor Disk Drive Model for locating the PCI expansion slots Figure 1 36 CDE285 L Drives For the procedure on installing OMD software on the CDE285 see Cisco UCS C240 M4 Server Installation and Service Guide Table 1 40 CDE285 S Expansion Cards PCI Expansion Slot Number Expansion Card 1 NIC dual 10GE fiber 2 NIC dual 10GE fiber 3 Blank 4 NIC dual 10GE fiber 5 NIC dua...

Страница 64: ...DE420 all models showing the location of the storage drives Table 1 43 lists the CDE420 4A F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 12 to see the location of the PCI expansion slots Table 1 42 CDE420 4A C Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC quad copper eth6 eth7 eth8 eth9 3 NIC quad copper eth2 eth3 eth4 e...

Страница 65: ...w of the CDE420 all models showing the location of the storage drives Table 1 45 lists the CDE420 4G F PCI expansion cards and their corresponding PCI slot numbers see Figure 1 12 to see the location of the PCI expansion slots Table 1 44 CDE420 4G C PCI Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 2 NIC quad copper eth6 eth7 eth8 eth9 3 NIC quad copper et...

Страница 66: ...heir corresponding PCI slot numbers Figure 1 38 CDE460 Front Drives Figure 1 39 CDE460 Rear Drives RESET 205501 disk3 disk2 disk1 disk6 disk5 disk4 disk9 disk8 disk7 disk12 disk11 disk10 disk15 disk14 disk13 disk18 disk17 disk16 disk21 disk20 disk19 disk24 disk23 disk22 Table 1 46 CDE460 Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 SAS Controller LSI SAS2...

Страница 67: ... their corresponding PCI slot numbers Figure 1 40 CDE460 4R1 Front Drives Figure 1 41 CDE460 4R1 Rear Drives RESET 205501 disk3 disk2 disk1 disk6 disk5 disk4 disk9 disk8 disk7 disk12 disk11 disk10 disk15 disk14 disk13 disk18 disk17 disk16 disk21 disk20 disk19 disk24 disk23 disk22 Table 1 47 CDE460 4R1 Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 SAS Contr...

Страница 68: ... their corresponding PCI slot numbers Figure 1 42 CDE460 4R3 Front Drives Figure 1 43 CDE460 4R3 Rear Drives RESET 205501 disk3 disk2 disk1 disk6 disk5 disk4 disk9 disk8 disk7 disk12 disk11 disk10 disk15 disk14 disk13 disk18 disk17 disk16 disk21 disk20 disk19 disk24 disk23 disk22 345086 disk25 disk26 disk27 disk28 disk29 disk30 disk31 disk32 disk33 disk34 disk35 disk36 Table 1 48 CDE460 4R3 Expans...

Страница 69: ... the storage drives and Figure 1 43 is a rear view of the CDE475 showing the location of the remaining 12 storage drives Table 1 49 lists the CDE475 PCI expansion cards and their corresponding PCI slot numbers Figure 1 44 CDE475 Front Drives Figure 1 45 CDE475 Rear Drives RESET 205501 disk3 disk2 disk1 disk6 disk5 disk4 disk9 disk8 disk7 disk12 disk11 disk10 disk15 disk14 disk13 disk18 disk17 disk...

Страница 70: ...l of the CDE220 and the CDE420 a reset button and an on off switch Figure 1 46 shows the location of the CDE205 CDE220 and CDE250 front panel control buttons and LEDs Figure 1 46 CDE205 CDE220 and CDE250 Front View Control Buttons and LEDs Table 1 49 CDE475 Expansion Cards PCI Expansion Slot Number Expansion Card Interface Name top to bottom 1 AOC S3108L H8IR 3108 SAS MegaRaid controller 2 AOC S31...

Страница 71: ...by power supplied to the system Therefore you must unplug the system before servicing it RESET The Reset button is used to reboot the system 204231 Cell Zone Power Failure When this LED flashes it indicates a power failure in the power supply Overheat Fan Fail When this LED flashes it indicates a fan failure When continuously on not flashing it indicates an overheat condition which may be caused b...

Страница 72: ...e system s power supply units This LED should be illuminated when the system is operating HD Indicates IDE channel activity on SAS or SATA drive or DVD ROM drive activity when flashing 2 204233 204236 204235 1 Hard drive fault LED on each drive tray 6 Fan status LED 2 Hard drive activity LED on each drive tray 7 Temperature status LED 3 Power button power status LED 8 Power supply status LED 4 Uni...

Страница 73: ...nctions Green The server is in main power mode Power is supplied to all server components 4 Unit Identification Off The unit identification function is not in use Blue The unit identification function is activated 5 System status Green The server is running in a normal operating condition Green blinking The server is performing system initialization and memory check Amber steady The server is in a...

Страница 74: ...uttons and LEDs 7 Temperature status Green The server is operating at normal temperature Amber steady One or more temperature sensors breached the critical threshold Amber blinking One or more temperature sensors breached the non recoverable threshold 8 Power supply status Green All power supplies are operating normally Amber steady One or more power supplies are in a degraded operational state Am...

Страница 75: ... Figure 1 49 shows the CDE280 rear panel LEDs and buttons Table 1 51 defines the LED states Figure 1 49 CDE280 Rear Panel LEDs and Buttons 1 Power supply fault LED 6 1 Gb Ethernet link speed LED 2 Power supply AC status LED 7 1 Gb Ethernet link status LED 4 1 Gb Ethernet dedicated management link speed LED 8 Unit Identification button LED 5 1 Gb Ethernet dedicated management link status LED ...

Страница 76: ... for advanced power supply LED information see Table 1 52 AC power supplies Off There is no AC power to the power supply Green blinking AC power OK DC output not enabled Green solid AC power OK DC outputs OK DC power supplies Off There is no DC power to the power supply Green blinking DC power OK DC output not enabled Green solid DC power OK DC outputs OK 4 1 Gb Ethernet dedicated management link ...

Страница 77: ...t Ports and Connectors The CDEs support the following I O connectors on the rear of the CDE Ethernet connector Serial connector Video and audio connectors on optional adapter Table 1 52 CDE280 Rear Power Supply LED States Green PSU Status LED State Amber PSU Fault LED State Event Solid on Off 12V main on main power mode Blinking Off 12Vmain off standby power mode Off Off No AC power input all PSUs...

Страница 78: ...ce the product installation is complete all I O cables except those installed in the Ethernet ports must be disconnected from the CDE to maintain EMC compliance Any other cable connections are temporary and are used only to initialize the system All PS 2 keyboard PS 2 mouse USB interface serial console interface and VGA interface cables must be disconnected from the front and rear I O ports of the...

Страница 79: ...your CDE before you begin the installation See Regulatory Compliance and Safety Information for Cisco UCS C Series Cisco C880 Series and C Series Based Appliances Site Requirements This section provides site requirements for the CDEs You should verify the site power prior to installing the CDEs Preventing Electrostatic Discharge Damage The CDEs have no user serviceable parts inside their chassis T...

Страница 80: ...asurement should be between 1 and 10 megohms Mohm Environmental and Physical Specifications The CDEs are tested to the environmental specifications indicated in Table 2 1 All testing is performed per procedures defined in Bellcore GR 63 CORE NEBS Physical Protection and Bellcore GR 1089 CORE EMC and Electrical Safety Generic Criteria for Network Telecommunications Equipment The CDE280 Engine shoul...

Страница 81: ...e drives Caution Do not strike the drive unit with another object or drive unit Caution Do not stack drive units on top of each other unless they are properly secured in a rack or chassis intended for stacking Caution Do not stand drive units on their edge They may fall over Table 2 2 Physical Dimensions Height CDE205 CDE220 and CDE250 CDE420 and CDE460 CDE280 CDE285 3 50 inches 8 90 cm 7 00 inche...

Страница 82: ...treme care during this operation to avoid shocking the other drives in the system Safety Warnings These warnings are translated into several languages in the Regulatory Compliance and Safety Information for the Cisco Content Delivery Engines document The Cisco Compliance label can be found on the CDE chassis in the following locations Chassis bottom CDE220 CDE420 Chassis top CDE250 CDE280 CDE460 W...

Страница 83: ...wiring is not overloaded Statement 1018 Warning The plug socket combination must be accessible at all times because it serves as the main disconnecting device Statement 1019 Warning To avoid electric shock do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports both use...

Страница 84: ...ng air through the chassis Do not operate the system unless all cards faceplates front covers and rear covers are in place Statement 1029 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning To prevent personal injury or damage to the chassis never attempt to lift or tilt the chassis using the handles on modules such as ...

Страница 85: ...t 1078 Warning Hazardous voltage or energy may be present on power terminals Always replace cover when terminals are not in service Be sure uninsulated conductors are not accessible when cover is in place Statement 1086 Warning Avoid using or servicing any equipment that has outdoor connections during an electrical storm There may be a risk of electric shock from lightning Statement 1088 Warning M...

Страница 86: ...low service markings Do not service any Cisco product except as explained in your system documentation Opening or removing covers that are marked with the triangular symbol with a lightning bolt may expose you to electrical shock Components inside these compartments should be serviced only by an authorized service technician If any of the following conditions occurs unplug the product from the ele...

Страница 87: ...reases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply UPS Position cables and power cords carefully route cables and the power cord and plug so that they cannot be stepped on or tripped over Be sure that nothing rests on your system components cables or power cord Do not modify power cables or plugs Consult a licensed electrician or your p...

Страница 88: ... Network CBN as defined by NEBS GR 1089 To ground the CDE to the rack when rack mounted connect an additional grounding conductor to the CDE by using the separate listed closed two hole crimp lug having 5 8 inch pitch It is recommended that the grounding conductor wire be number 12 to number 10 AWG with green insulation rated minimum167 F 75 C low smoke fume LSF and flame retardant The ground conn...

Страница 89: ...s of two screws that are mounted on the rear of the chassis see Figure 2 2 Figure 2 2 CDE280 Rear View For information about the CDE285 grounding connections see Cisco UCS C240 M4 Server Installation and Service Guide For the CDE420 grounding conductor consists of two screws that are mounted on the rear of the chassis see Figure 2 3 Figure 2 3 CDE420 Rear View 1 Grounding lug holes 1 Grounding scr...

Страница 90: ...ure the cables with nylon tie wraps Source DC power disconnect You are responsible for installing a properly rated DC power disconnect for the CDE system This source disconnect must be readily accessible and it must be labeled as controlling power to the CDE The circuit breaker of a centralized DC power system may be used as a disconnect device when easily accessible and should be rated no more th...

Страница 91: ...CDE type as defined in Appendix A Technical Specifications Extreme fluctuations in temperature can cause a variety of problems in your CDE To maintain proper cooling the equipment rack must provide sufficient airflow to the front of the CDE The rack selected and the ventilation provided must be suitable to the environment in which the CDE will be used The rack must include ventilation sufficient t...

Страница 92: ...2 14 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Chapter 2 Preparing to Install the Content Delivery Engines Safety Guidelines ...

Страница 93: ... and CDE460 Antistatic mat Properly grounded ESD preventive device 1 4 inch flat blade screwdriver 3 16 inch flat blade screwdriver Number 2 Phillips screwdriver Unpacking the Box Each Cisco CDE is securely packaged in a shipping box The cards and power supplies ship installed in the CDEs Caution Proper ESD protection is required whenever you handle Cisco equipment Installation and maintenance per...

Страница 94: ...any components to Cisco Verify that your shipment is complete by making sure you received everything on your packing list and then comparing the packing list to your order If any items are missing or if you need additional information contact Cisco Technical Support at the following URL http www cisco com cisco web support index html Inspecting for Damage After you verify that all of the equipment...

Страница 95: ...g multiple devices in the rack Do not place any object weighing more than 110 lb 50 kg on top of rack mounted devices Preparing the CDEs for Rack Installation The rack must be of the following type A standard 19 in 48 3 cm wide four post EIA rack with mounting posts that conform to English universal hole spacing per section 1 of ANSI EIA 310 D 1992 The rack post holes can be square 0 38 inch 9 6 m...

Страница 96: ...d12 proc cds cdd remove_device A few moments later the message Disk device 12 has been removed from the file system appears on the console and you can now remove the storage drive from the CDE Once you insert the new storage drive you must first enter the following command on the Linux console at user root echo csd12 proc cds cdd make_well A few moments later the message Found disk device 12 appea...

Страница 97: ...ve The storage drives are mounted in storage drive trays to simplify their installation and removal from the chassis see Figure 3 2 These trays also help promote proper airflow for the drive bays Note If you need to replace a storage drive be sure to keep the existing storage drive tray because spare storage drives do not ship with storage drive trays 1 Storage drive tray 2 Release tab 370025 1 2 ...

Страница 98: ...CDEs Figure 3 2 Storage Drive Tray Step 3 Remove the two screws securing the dummy drive to the drive tray and remove the dummy drive Place the storage drive tray on a flat surface see Figure 3 3 Figure 3 3 Removing a Storage Drive Step 4 Slide the storage drive into the storage drive tray with the printed circuit side facing down see Figure 3 4 370026 370027 ...

Страница 99: ...torage Drive into the Storage Drive Tray Step 5 Carefully align the mounting holes in both the drive tray and the storage drive Step 6 Secure the storage drive to the tray using six screws see Figure 3 4 Step 7 Replace the drive tray into the chassis Make sure to close the drive tray handle to lock the drive tray into place see Figure 3 5 1 Storage drive tray 2 Storage drive 370028 1 2 2 ...

Страница 100: ...Remove the drive that you are replacing or remove a blank drive tray from an empty bay a Press the release button on the face of the drive tray See Figure 3 6 b Grasp and open the ejector lever and then pull the drive tray out of the slot c If you are replacing an existing drive remove the four drive tray screws that secure the drive to the tray and then lift the drive out of the tray Step 2 Insta...

Страница 101: ...ce the power supply Step 1 Turn off the AC DC power source that is providing power for the failed power supply Before proceeding the failed power supply status LED must indicate that power to this power supply is off See Figure 3 7 for the location of the status LED If the status LED is off it indicates no power to all power supplies If the status LED is amber it indicates the CDE is off but there...

Страница 102: ...ve nodes see Figure 3 7 Figure 3 7 Rear View of the DC Power Supply Note For additional information on DC power supplies see the If DC Power Supplies Are Installed section on page 12 Note The CDE220 has an additional grounding bracket for grounding both AC and DC power supplies See the Supplemental Grounding Connection section on page 2 10 for instructions on installing this bracket Step 3 Push th...

Страница 103: ...ent Delivery Engines Installing the CDEs Figure 3 8 Power Supply Release Tab on a CDE205 and CDE220 Figure 3 9 Power Supply Release Tab on a CDE420 Step 4 Pull the power supply out using the handle on the front of the power supply see Figure 3 10 1 Power supply 2 Release tab 204337 2 1 1 Power supply 2 Release tab 1 2 204259 ...

Страница 104: ... following actions If your server has only one power supply shut down and power off the server If your server has two power supplies you do not have to shut down the server b Remove the power cord from the power supply that you are replacing For a DC power supply release the electrical connector block from the power supply by pushing the orange plastic button on the top of the connector inward tow...

Страница 105: ...f For VDS TV versions prior to Version 3 4 1 this test can be performed by echoing 1 to the proc cds cdd identify_dev proc file for example echo 1 proc cds cdd identify_dev The test pattern repeats until a 0 is echoed to the proc file This test has no effect on normal device operations We do not recommended however that this test be performed while a device currently has its red LED lit because it...

Страница 106: ... Kit page 3 24 To install a CDE in a rack using the rail kit see Installing a CDE205 CDE220 CDE420 and CDE460 in the Rack Using a Rev B Rail Kit page 3 24 To install a CDE280 in a rack using the rail kit see Installing a CDE280 in the Rack Using a Rail Kit page 3 30 Note The slide rails supplied by Cisco Systems for the CDE280 engine does not require tools for installation if you install them in a...

Страница 107: ... out for servicing Inner Rail Extension The inner rails are preattached and do not interfere with normal use of the chassis if you decide not to use a rack Attach the inner rail extensions to stabilize the chassis within the rack If you are not using a rack you do not have to install the inner rail extensions Installing the Rev A Inner Rails Perform the following steps to install the inner rails S...

Страница 108: ...ep 4 Repeat Step 1 through Step 3 for the other inner rail extension Installing the Rev A Outer Rails to the Rack Outer rails attach to the rack and hold the CDE in place The outer rails for the CDE205 CDE220 chassis extend between 30 inches and 33 inches Perform the following steps to install the outer rails to the rack Step 1 Attach the short bracket to the outside of the long bracket You must a...

Страница 109: ...just both the short and long brackets to the proper distance so that the rail fits snugly into the rack Step 3 Secure the long bracket to the front side of the outer rail with two M5 screws and the short bracket to the rear side of the outer rail with three M5 screws see Figure 3 14 Step 4 Repeat Step 1 through Step 3 for the other outer rail 1 Long bracket end 2 Slides 3 Pins 4 Short bracket end ...

Страница 110: ...des the inner rails and rail extensions Also confirm that the outer rails are installed on the rack see Figure 3 16 Step 2 Align chassis rails with the front of the rack rails Step 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting the chassis rails When the CDE has been pushed completely into the rack you s...

Страница 111: ...ls about replacing the CDE285 see Cisco UCS C240 M4 Server Installation and Service Guide Installing a CDE420 in the Rack Using a Rev A Rail Kit This section provides information on installing the CDE420 chassis into a rack with the Rev A rails kit There are a variety of racks on the market which may mean that the assembly procedure will differ slightly You should also refer to the installation in...

Страница 112: ...ectly to the rack see Figure 3 16 Figure 3 16 Identifying the Rev A Inner Rails Installing the Rev A Inner Rails Perform the following steps to install the inner rails Step 1 Place the inner rails on the side of the chassis aligning the hooks of the chassis with the inner rail holes Make sure the rail faces outward so that it will fit with the rack mounting bracket see Figure 3 17 Step 2 Slide the...

Страница 113: ... to the Rack Outer rails attach to the rack and hold the CDE in place The outer rails for the CDE205 CDE220 chassis extend between 30 inches and 33 inches Perform the following steps to install the outer rails to the rack Step 1 Attach the short bracket to the outside of the long bracket You must align the pins with the slides Also both bracket ends must face the same direction see Figure 3 18 1 C...

Страница 114: ...djust both the short and long brackets to the proper distance so that the rail fits snugly into the rack Step 3 Secure the long bracket to the front side of the outer rail with two M5 screws and the short bracket to the rear side of the outer rail with three M5 screws see Figure 3 19 Step 4 RepeatStep 1 through Step 3 for the other outer rail 1 Long bracket end 2 Slides 3 Pins 4 Short bracket end ...

Страница 115: ... the inner rails and rail extensions Also confirm that the outer rails are installed on the rack see Figure 3 20 Step 2 Align the chassis rails with the front of the rack rails Step 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting the chassis rails When the CDE has been pushed completely into the rack you ...

Страница 116: ...vious Rev A rail kit components from the rack completely before you install the new rails Do not mix and match any components from Rev A and Rev B rail kits The Rev B rail kit comes in two sizes The long range rail kit ships with all CDEs and the short range rail kit can be ordered from Cisco Depending on rack depth if the accompanying long rail kit is too long for the rack obtain the shorter rail...

Страница 117: ...rom the rail assembly Figure 3 22 Releasing the Rev B Inner Rails Step 3 Place the inner rails on the side of the chassis aligning the hooks of the chassis with the inner rail so that it snaps securely Make sure that the rail faces outward so that it fits with the rack mounting bracket see arrow number 1 Slide the inner rail forward until it clicks into the locked position see arrow number 2 1 Inn...

Страница 118: ...pter 3 Installing the Content Delivery Engines Installing the CDEs Figure 3 23 Attaching the Rev B Rails to the CDE Step 4 Secure the inner rails with screws optional Step 5 Press the locking tab and push the middle rail back into the outer rail 1 CDE 2 Rail assemblies 3 Screws 1 2 209586 2 2 1 3 3 ...

Страница 119: ... Rails Step 6 Hang the hooks of the rails on the rack holes and press down so they are completely seated If necessary secure the rails with screws Figure 3 25 Attaching the Rev B Rack Rails to the Rack Step 7 Repeat Step 6 to mount the four ends extending the rails as necessary 1 Outer rail assembly 2 Middle rail assembly 3 Locking tab 209588 2 1 3 1 Rack 2 Rail hooks 3 Screws 1 2 209589 3 1 2 ...

Страница 120: ... 3 26 Extending the Rev B Rails Step 8 Pull the middle rail out of the front of the outer rail and make sure the ball bearing shuttle is locked at the front of the middle rail Align the inner rail with the middle rail and then push evenly on both sides of the chassis until it clicks into the fully extended position 1 Outer rail assembly 2 Middle rail assembly 209590 1 2 ...

Страница 121: ...r Rails to the Middle and Outer Rails Step 9 Depress the locking tabs on both sides of the chassis simultaneously and push the chassis all the way into the rear of the rack Step 10 If additional security is required secure the chassis handles to the front of the rack with two screws optional 1 Outer rail assembly 2 Inner rail assembly 3 Middle rail assembly 4 Ball bearing shuttle 209591 3 1 2 4 ...

Страница 122: ... page 3 33 Note Before you install operate or service a server review the Regulatory Compliance and Safety Information for the Cisco Content Delivery Engines for important safety information Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical ci...

Страница 123: ... Step 2 Compare the shipment to the equipment list provided by your customer service representative Verify that you have all items Step 3 Check for damage and report any discrepancies or damage to your customer service representative Have the following information ready Invoice number of shipper see the packing slip Model and serial number of the damaged unit Description of damage Effect of damage...

Страница 124: ...d when you mount the units using rail kits Caution Avoid UPS types that use ferroresonant technology These UPS types can become unstable with systems such as the Cisco UCS which can have substantial current draw fluctuations from fluctuating data traffic patterns When you are installing a server use the following guidelines Plan your site configuration and prepare the site before installing the se...

Страница 125: ...Installing the Slide Rails This section describes how to install the server in a rack using the rack kits that are sold by Cisco Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if...

Страница 126: ...een arrow button toward the rear to open the securing plate Figure 3 30 Front Securing Mechanism Inside of Front End Step 3 Install the slide rails into the rack a Align one slide rail assembly front end with the front rack post holes that you want to use The slide rail front end wraps around the outside of the rack post and the mounting pegs enter the rack post holes from the outside front see Fi...

Страница 127: ...e alone could result in personal injury or equipment damage a Align the rear of the inner rails that are attached to the server sides with the front ends of the empty slide rails on the rack b Push the inner rails into the slide rails on the rack until they stop at the internal stops c Slide the release clip toward the rear on both inner rails Figure 3 31 and then continue pushing the server into ...

Страница 128: ...ep 3 Pull out the width adjustment slider that is at the opposite end of the CMA assembly until it matches the width of your rack see Figure 3 32 Step 4 Slide the CMA tab that is at the end of the width adjustment slider onto the end of the stationary slide rail that is attached to the rack post see Figure 3 32 Slide the tab over the end of the rail until it clicks and locks Step 5 Open the hinged...

Страница 129: ...d network connections Caution The unit is intended for indoor use and is provided with numerous standard USB and Ethernet ports This product is not intended to be directly connected to the Telecommunication Network System Additional regulatory compliance and legal requirements may apply for direct connection to the Telecommunication Network System This product may connect to the Telecommunication ...

Страница 130: ...ent Delivery System Manager CDSM CDE205 Service Engine SE CDE205 CDE220 CDE250 or CDE280 Service Router SR CDE205 or CDE220 Depending on your application you may have multiple SEs and SRs A network switch is employed to link multiple servers together within a larger network There are six distinct server types in VDS TV Management Server CDSM VVIM CDE110 TV Streamer CDE220 models 2C1 2C2 2S3 and CD...

Страница 131: ...ng the Content Delivery Engines Installing the Server In a Rack Note Once the CDEs are powered up a Cisco technician will initially configure the CDEs to communicate properly Further configuration is accomplished through the CDSM See the Cisco Internet Streamer CDS Software Configuration Guide for more information ...

Страница 132: ...3 40 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Chapter 3 Installing the Content Delivery Engines Installing the Server In a Rack ...

Страница 133: ...o to Launching a New CDE for the First Time section on page 4 1 If you need to upgrade or downgrade the software version of a VDS IS system running on a CDE see the Software Upgrade section in the Cisco Internet Streamer CDS Software Configuration Guide Note For the procedure on installing VQE software on the CDE250 2V0 see the Installing VQE Release 3 6 Software section of the Release Notes for C...

Страница 134: ...uit this session Please choose an interface to configure from the following list 1 GigabitEthernet 1 0 2 GigabitEthernet 2 0 3 GigabitEthernet 3 0 4 GigabitEthernet 4 0 5 GigabitEthernet 5 0 6 GigabitEthernet 6 0 7 GigabitEthernet 7 0 8 GigabitEthernet 8 0 9 GigabitEthernet 9 0 10 GigabitEthernet 10 0 Enter choice 1 Please enter the IP address of this interface XXX XXX XXX XXX Please enter the net...

Страница 135: ...strongly recommended that you leave this connection as a permanent connection There should be a permanent IP address and a cable permanently connected to switch router associated with this connection The CIMC will benefit monitoring general troubleshooting and troubleshooting system alarms of this system Step 1 Attach an Ethernet cable to the Management port of the CDE280 and also attach a monitor...

Страница 136: ... NIC Redundancy settings If these are set incorrectly CIMC configures itself to use network ports other than the dedicated CIMC port causing issues We recommend that you set the NIC mode to Dedicated and the NIC redundancy to None Step 4 Ping the IP address associated with the CIMC port Step 5 After verifying the CIMC interface is reachable verify that the CIMC Web Interface is available by pointi...

Страница 137: ...y Configuring a CDE Launching a New CDE for the First Time Figure 4 3 CIMC Main Webpage Configure Remote Presence To get access to the serial port of CDE280 you have to configure the settings Step 7 Select Remote Presence from the left pane a Select Virtual KVM and check the Enabled check box b Set Max Sessions to 4 c Set Remote Port to 2068 d Click Save Changes ...

Страница 138: ... 4 Installing the VDS Internet Streamer Software and Initially Configuring a CDE Launching a New CDE for the First Time Figure 4 4 Configuring Remote Presence Virtual KVM Step 8 Select Virtual Media a Check the Enabled check box b Click Save Changes Figure 4 5 Configuring Remote Presence Virtual Media ...

Страница 139: ...n the password same as CIMC login webpage default password as password You have to use a ssh client or a ssh terminal software to access CIMC IP address user1 ssh l admin 10 140 104 17 admin 10 140 104 17 s password XXXXX C240 FCH1852V20Y Step 11 Enter the following command C240 FCH1852V20Y connect host Configure VDS IS Software Step 12 Enter the following commands to assign a primary interface CD...

Страница 140: ...p XXX XX X X Please enter the domain name cisco com Please enter the hostname ST2 CDE280 2 Please enter CDSM Content Delivery System Manager IP or Host name XXX XXX XXX X CDE configure CDE config This process initiates database services on the device that you just configured If you want to configure a port channel use the CLI See Configuring a Port Channel in the Cisco Internet Streamer CDS Softwa...

Страница 141: ...the designated host Note After you check this check box you need to click Save Changes before you can configure SNMP users or traps SNMP Port field The port on which Cisco IMC SNMP agent runs Enter an SNMP port number within the range 1 to 65535 The default port number is 161 Note The port numbers that are reserved for system calls such as 22 23 80 123 443 623 389 636 3268 326 9 and 2068 cannot be...

Страница 142: ...n Trap Destinations tab Step 5 In the Trap Destinations area you can perform one of the following Select an existing user from the table and click Modify Click Add to create a new user Note If the fields are not highlighted select Enabled Step 6 In the Trap Details dialog box complete the following fields Trap Community String field The name of the SNMP community group used for sending SNMP trap t...

Страница 143: ... ID field The trap destination ID This value cannot be modified Enabled check box If checked then this trap is active on the server Version drop down list The SNMP version and model used for the trap This can be one of the following V2 V3 Trap Type radio button The type of trap to send This can be one of the following Trap If this option is chosen the trap will be sent to the destination but you d...

Страница 144: ...ep 2 On the Admin tab click Communications Services Step 3 In the Communications Services pane click the SNMP tab Step 4 In the SNMPV3 Users area update the following properties Step 5 Click Save Changes Configuring SNMPv3 Users Before You Begin check the following You must log in as a user with admin privileges to perform this task Table 4 3 SNMPV3 Users Properties Name Description Add button Cli...

Страница 145: ...s field cannot be changed Name field The SNMP username Enter between 1 and 31 characters or spaces Note Cisco IMC automatically trims leading or trailing spaces Security Level drop down list The security level for this user This can be one of the following no auth no priv The user does not require an authorization or privacy password auth no priv The user requires an authorization password but not...

Страница 146: ... chassis drive bay expanders not labeled CDE220 chassis drives vary by CDE model see Table 1 5 on page 1 17 for a list of models and drives CDE250 chassis drives vary by CDE model see Table 1 6 on page 1 19 for a list of models and drives CDE280 chassis drives vary by CDE model see Table 1 7 on page 1 21 for a list of models and drives External USB DVD ROM drive or CD ROM drive Internal IDE Compac...

Страница 147: ...rience Application Release 3 11 Console connection Note For CDE280 you don t need to connect console port physically Note On the CDE use the USB port to connect the external USB DVD ROM drive Use the external USB DVD ROM drive for all procedures that require a DVD ROM drive After the initial installation remove the external USB DVD ROM drive The internal IDE CF drive becomes the boot drive for sub...

Страница 148: ...his installer you can configure your hardware and install CDS IS software on it The installer can also be used to modify an existing hardware configuration Output truncated System type CDE250 2S6 Software status Successfully installed 1 Configure Hardware 2 Install all software 3 Exit Choice Step 7 From the Installer Main Menu choose Option 2 to install the software on the CDE and clear the unnece...

Страница 149: ... unmounting sw done unmounting state done unmounting local local1 done unmounting disk23 01 done unmounting disk22 01 done unmounting disk21 01 done unmounting disk20 01 done unmounting disk19 01 done unmounting disk18 01 done unmounting disk17 01 done Step 10 Eject the CD from the DVD ROM drive disconnect the DVD ROM drive from the CDE Re manufacturing and Installing CDE280 To install the CDE280 ...

Страница 150: ... Guide Chapter 4 Installing the VDS Internet Streamer Software and Initially Configuring a CDE Re manufacturing a CDE Figure 4 7 Configuring Boot Order b Select the Add virtual media and then select KVM mapped DVD Figure 4 8 Adding Virtual Media c Click the Add device and then Save Changes ...

Страница 151: ...tep 2 Mount a virtual ISO a Navigate to the Summary section of the CIMC and click the Launch KVM Console to launch the console Figure 4 9 Launching KVM Console Note You may be prompted several times before you get to the KVM console b In the prompt KVM console from the Virtual Media tab select Activate Virtual Devices Figure 4 10 Activating Virtual Devices c From the Virtual Media tab select the M...

Страница 152: ...D d From the Drive Image File drop down list select the iso image Figure 4 12 Selecting ISO image e Click Map Device Step 3 Reboot the server From the Power tab select Power Cycle Systems cold boot to reboot the server Figure 4 13 Rebooting the Server Step 4 Install the VDS IS Software for CDE280 a Connect to the serial console of CDE280 Enter the IP address of the server with admin as the usernam...

Страница 153: ...Output truncated System type CDE280 2S5 Software status Successfully installed 1 Configure Hardware 2 Install all software 3 Exit Choice Note This may take approximately 10 to 20 minutes Step 6 From the Installer Main Menu choose Option 2 to install the software on the CDE and clear the unnecessary data You should see a display similar to this Choosing this option will delete all software and data...

Страница 154: ...ing swstore done unmounting sw done unmounting state done unmounting local local1 done unmounting disk23 01 done unmounting disk22 01 done unmounting disk21 01 done unmounting disk20 01 done unmounting disk19 01 done unmounting disk18 01 done unmounting disk17 01 done Note There may be slight variations in the output Step 9 Un mount the ISO file From the Virtual Media tab select Activate Virtual D...

Страница 155: ... to that the external disk will be formatted and no caches contents will be preserved The main difference between the 6 sub prototypes is the drives Table 4 5 lists the internal and external drives of each CDE280 sub prototype For example to migrate from CDE280 2S5 to CDE280 2S10 do the following Step 1 Switch off the device by clicking the Power button on the front panel of the device Step 2 Pull...

Страница 156: ...ceed with model update y n y SE DISK 0 200047 Stopping all services this may take several minutes INIT Switching to runlevel 4 INIT Sending processes configured via etc inittab the TERM signal INIT Sending processes configured via etc inittab the KILL signal Recoverying CDNFS volumes CDNFS recovery complete unmounting swstore done unmounting sw done unmounting state done unmounting local local1 do...

Страница 157: ... them This section will explain how to manufacture a spare lite CDE280 chassis into a CDE280 sub prototype Requirement A CDE280 spare lite chassis Corresponding drives Table 4 6 lists the CDE280 sub prototype and its external drives After this process drives loses its data For example to manufacture a spare lite CDE280 chassis into CDE280 2S5 do the following Step 1 Configure the CIMC and remote p...

Страница 158: ... make sure the system is offline Proceed with model update y n y SE DISK 0 200047 Stopping all services this may take several minutes INIT Switching to runlevel 4 INIT Sending processes configured via etc inittab the TERM signal INIT Sending processes configured via etc inittab the KILL signal Recoverying CDNFS volumes CDNFS recovery complete unmounting swstore done unmounting sw done unmounting s...

Страница 159: ...stallation of a new software image onto your system or recover a previous image in the event that the hardware was changed MODEL CDE205 FLASH found directory validated COOKIE valid IMAGE DEVELOPMENT vcn build2 auto vcn u1 carlowan refact dev 1 spcdn FLASHDEV dev hda Installer Main Menu 1 Configure Network 2 Manufacture flash 3 Install flash cookie 4 Install flash image from network 5 Install flash...

Страница 160: ...s and install bin image 8 Exit and reboot 9 Force manufacturing flash Choice 0 Step 4 Choose Option 5 to install the flash image from the CD ROM drive You should see something like this Please select an image from the following list 1 CDS23 sysimg 2 Return to Main Menu Image 1 Step 5 Choose Sub option 1 to select an image and enter Y when prompted to confirm and proceed with the flash write You sh...

Страница 161: ... for Model CDE205 Reclaiming unused flash safe state sectors Done 253105823 bytes transferred in 81 5 seconds 2 96 MBps Installing phase3 bootloader Installing system image to flash done cat etc PERSONALITY No such file or directory Installing application components ap di jr li me pe to un Running post install hooks Syncing filesystems ruby bin install to sw DONE Successfully installed product ima...

Страница 162: ...ore rebooting the system or the system will not boot with the normal image Verifying the CDSM Perform the following steps to verify that the remanufactured device is operational from CDSM Step 1 Launch a web browser and enter the IP address of the CDSM using the following format https CDSM_IP_address 8443 The CDSM Login page appears see Figure 4 16 Figure 4 16 CDSM Login Page Step 2 Enter admin as...

Страница 163: ...them using the Device Activation page See the Activating a Service Engine section in the Cisco Internet Streamer CDS 3 0 Software Configuration Guide Figure 4 18 Devices Page Step 4 Verify that the devices you configured for your VDS network are listed Step 5 If a device is not listed restart the CMS for that device by using either the console or a Telnet connection and enter the following command...

Страница 164: ...de see This appendix contains the following sections page F 1 You do not need to edit the BIOS for any reason when installing or re manufacturing a CDE205 CDE220 CDE250 or CDE280 If you have made changes to any of the BIOS screens you need to return them to their default configuration The original BIOS screens are shown in Figure 4 19 through Figure 4 23 For the CDE280 BIOS Settings see Table 4 7 ...

Страница 165: ...5 420 460 475 Hardware Installation Guide Chapter 4 Installing the VDS Internet Streamer Software and Initially Configuring a CDE Re manufacturing a CDE Figure 4 20 Main BIOS Screen IDE Channel 0 Master Figure 4 21 Advanced BIOS Screen Console Redirection ...

Страница 166: ... Internet Streamer Software and Initially Configuring a CDE Re manufacturing a CDE Figure 4 22 Advanced BIOS Screen Boot Features Figure 4 23 Boot BIOS Screen CDE280 BIOS and CIMC Settings Table 4 7 describes the CDE280 BIOS and CIMC Settings Table 4 7 CDE280 BIOS and CIMC Settings Settings Adopter Setting Lockdown Versions ...

Страница 167: ...e admin SW Passsword default SW Installation Procedure CIMC Settings Server Power Restore policy power off Fan Policy balanced Network NIC Mode dedicated NIC Redundancy none SOL Serial Over LAN Enabled yes Baud rate 115200 BIOS Boot Order Setting Shipping Order Boot order HDD Slot 9 INTEL SSDSC2BB480G4 hdd BIOS Main Shipping Order TPM Support disabled BIOS Advanced Settings Processos Configuration...

Страница 168: ...step R Tec enabled Intel R Turbo Boost Technology enabled Processor Power state C6 enabled Processor Power state C1 Enhanc enabled P STATE Coordination HW ALL Energy Performance balaned performance Workload Configuration balanced Extended APIC XAPIC Server ME configuration Altitude 80000000 MCTP Bus Owner 0 Memory Configuration Select Memory RAS maximum performance NUMA enabled Channel Interleavin...

Страница 169: ...ys enable LOM and PCIe slot Configuration PCI ROM CLP disabled PCH SATA Mode AHCI All Onboard LOM Ports enabled LOM Port 0 OptionROM enabled LOM Port 1 OptionROM enabled All PCIe Slots OptionROM enabled PCIe Slot 1 OptionROM enabled PCIe Slot 2 OptionROM enabled PCIe Slot 3 OptionROM disabled PCIe Slot 4 OptionROM enabled PCIe Slot 5 OptionROM enabled PCIe Slot 6 OptionROM enabled PCIe Slot MLOM O...

Страница 170: ... Streamer Software and Initially Configuring a CDE Re manufacturing a CDE Possible Use Automatic Settings Server Management wait for BMC Disabled Clear System Event Log No FRB 2 Timer Enabled OS Watchdog Timer Disabled OS Watchdog Timer Timeout 10 mins OS Watchdog Timer Policy Reset Table 4 7 CDE280 BIOS and CIMC Settings continued ...

Страница 171: ...n on the Hardware or platform specific perfomance numbers for VDS TV Table 5 1 VDS TV Hardware Models Hardware Models Device Type Performance Numbers CDE110 CDSM VVIM Transactions Sec of PlayoutHistory 200 UCS220M4 CDSM VVIM Transactions Sec of PlayoutHistory 1000 CDE420 Vault Ingest Max parallel 10 RTSP 21 ISA Throughput 1Gig Ingest link Approx 780Mbps Max Fills Approx 5 75Gbps CDE420 CGW Max Str...

Страница 172: ...s ISA Throughput 10 Gig Ingest link Approx 4800Mbps ISA Max Fills Approx 25Gbps CDE475 4A1 Vault Ingest Max parallel 10 RTSP 42 ISA Throughput 1Gig Ingest link Approx 944Mbps RTSP Approx 925Mbps ISA Throughput 10 Gig Ingest link Approx 5210Mbps ISA Max Fills Approx 26Gbps ISA and RTSP CDE250 2A4 Vault Ingest Max parallel 10 RTSP 21 ISA Throughput 1Gig Ingest link Approx 780Mbps Mirroring Approx 8G...

Страница 173: ...ut 37 5Gbps CDE280 2U1 Streamer Max Streams Cache Miss 3600 Tput 13 5Gbps Max Streams Cache Hit 7998 Tput 30Gbps CDE280 2U2 Streamer Max Streams Cache Miss 3645 Tput 13 6Gbps Max Streams Cache Hit 9997 Tput 37 4Gbps CDE280 2U3 Streamer Max Streams Cache Miss 4245 Tput 15 9Gbps Max Streams Cache Hit 11999 Tput 45 0Gbps CDE280 2U3 CGW Max Streams Cache Miss 2800 Tput 10 5Gbps Max Streams Cache Hit 9...

Страница 174: ...42 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Chapter 5 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide ...

Страница 175: ... on page 6 1section on page If you need to re manufacture a CDE for any reason see the Re manufacturing a CDE section on page 6 2 Launching a New CDE250 for the First Time To launch a CDE250 for the first time see VQE Software Installation Types section in the Release Notes for Cisco CDA Visual Quality Experience Application Release 3 11 Launching a New CDE280 for the First Time For CDE280 you can...

Страница 176: ...a CDE If your CDE250 and CDE280 has failed and is no longer booting up or functioning properly you must perform a full re manufacturing of the CDE The general re manufacturing process is as follows Before You Begin page 6 2 Installing a CDE page 6 3 Re Manufacturing and Installing CDE280 page 6 3 Installing the VQE Software page 6 6 BIOS Settings page 6 7 Before You Begin You need the following to...

Страница 177: ...tep 3 Attach a power cord and keyboard to the CDE and attach a terminal server to the CDE serial port and ensure the serial communications are properly configured see Figure 1 9 on page 1 10 Step 4 Insert the VQE installation image CD in the DVD ROM drive The system boots from the image on the CD This requires a terminal server to be connected to the serial port of the CDE All communication is don...

Страница 178: ...lowing the installation This boot order change is permanent To change the boot order temporarily see ISO Clean Installation section in the Release Notes for Cisco CDA Visual Quality Experience Application Release 3 11 b Select the Add virtual media and then select KVM mapped DVD see Figure 4 8 on page 4 18 c Click the Add device and then Save Changes Step 2 Mount a virtual ISO a Navigate to the Su...

Страница 179: ...ing the VQE and Initially Configuring a CDE Re manufacturing a CDE Figure 6 3 Mapping CD or DVD d From the Drive Image File drop down list select the iso image Figure 6 4 Selecting ISO Images e Click Map Device Step 3 Reboot the server From the Power tab select Power Cycle Systems cold boot to reboot the server ...

Страница 180: ...ly five minutes Allow the booting to proceed and monitor the sequence from a remote terminal provided by the terminal server The Installer main menu is displayed at the conclusion of the boot sequence you should see a menu similar to this Step 6 Un mount the ISO file From the Virtual Media tab select Activate Virtual Devices Note When you select Activate Virtual Devices the system prompts whether ...

Страница 181: ...ery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Chapter 6 Installing the VQE and Initially Configuring a CDE Re manufacturing a CDE BIOS Settings For BIOS setting see BIOS Settings section on page 4 32 ...

Страница 182: ...6 8 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Chapter 6 Installing the VQE and Initially Configuring a CDE Re Manufacturing a CDE ...

Страница 183: ...ifications page A 5 CDE460 Specifications page A 6 CDE475 Specifications page A 7 CDE Management page A 7 CDE Management page A 7 CDE Heat Rate Load page A 8 CDE205 Specifications Table A 1 lists the technical specifications and management information for the CDE205 Table A 1 CDE205 Specifications Rack Units 2 Power 100 to 240 VAC or 48 VDC single power supply optional redundant power supply avail...

Страница 184: ...ions H x W x D 3 5 x 17 2 x 25 5 in 8 9 x 43 7 x 64 8 cm Weight fully configured 52 lb 23 58 kg Approvals Safety UL CSA 60950 1 Approvals EMC FCC Part 15 CFR 47 Class A Table A 1 CDE205 Specifications Rack Units 2 Table A 2 CDE220 Specifications Rack Units 2 Power 100 to 240 VAC or 48 VDC redundant power supplies included in all models Power Rating 800 W peak DC Power Rating 710 W peak AC Electric...

Страница 185: ...C self ranging 180 to 264 VAC nominal Power Rating 1200 W peak DC Power Rating 930W peak AC Electrical Input 11 Amps maximum at 100 VAC 7 Amps maximum at 208 VAC DC Electrical Input 48 to 60 VDC nominal self ranging 40 to 72 VDC DC Connector Type Amphenol Power Connector Cables Wire cable gauge 12 AWG Operating Relative Humidity 10 to 90 non condensing at 82 F 28 C Nonoperating Relative Humidity 5...

Страница 186: ...d Service Guide Side Clearance 1 in 25 mm Rear Clearance 6 in 152 mm Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000 3 3 KN22 Class A CNS13438 Class...

Страница 187: ...ge Minimum 200 VAC Maximum 240 VAC See the If AC Power Supplies Are Installed section on page 2 9 DC Electrical Input DC input voltage range 48 VDC to 60 VDC See also the If DC Power Supplies Are Installed section on page 2 12 DC Connector Type Molex Power Connector Cables Wire cable gauge 8 AWG Operating Relative Humidity 8 to 90 non condensing Nonoperating Relative Humidity 5 to 95 non condensin...

Страница 188: ...AC Power Supplies Are Installed section on page 2 9 DC Electrical Input DC input voltage range 48 VDC to 60 VDC See also the If DC Power Supplies Are Installed section on page 2 12 DC Connector Type Molex Power Connector Cables Wire cable gauge 10 AWG Operating Relative Humidity 8 to 90 non condensing Nonoperating Relative Humidity 5 to 95 non condensing at temperatures of 73 F to 104 F 23 C to 40...

Страница 189: ...on on page 2 9 DC Electrical Input DC input voltage range 48 VDC to 60 VDC See also the If DC Power Supplies Are Installed section on page 2 12 DC Connector Type Molex Power Connector Cables Wire cable gauge 10 AWG Operating Relative Humidity 8 to 90 non condensing Nonoperating Relative Humidity 5 to 95 non condensing at temperatures of 73 F to 104 F 23 C to 40 C Operating Temperature 50 to 95 F 1...

Страница 190: ...CDE205 300 1025 CDE220 2A 665 2275 CDE220 2C1 435 1500 CDE220 2C2 635 2175 CDE220 2D1 475 1625 CDE220 2G2 550 1885 CDE250 2G3 600 2052 CDE250 2M0 600 2047 CDE220 2S1 385 1325 CDE220 2S3 510 1750 CDE250 2S5 450 1550 CDE250 2S6 450 1550 CDE250 2S8 450 1535 CDE250 2S9 450 1535 CDE250 2S10 450 1535 CDE250 2S10 450 1535 CDE250 2V0 450 1535 CDE280 2S5 540 1843 CDE280 2S10 514 1754 CDE280 2S21 520 1774 C...

Страница 191: ...odem cable is required to connect a workstation running the Linux or Windows operating system Table B 1 lists the pin assignments for the serial console interface connector Table B 1 RS 232 Connector Pin Assignments Description Pin I O Signal Name Data carrier detect input 1 In DCD Receive data input 2 In RXD Transmit data output 3 Out TXD Data terminal ready output 4 Out DTR Interface signal grou...

Страница 192: ...n number assignments conform to the industry standard for RS 232 communications Figure B 1 Serial Port Connector Table B 3 provides the RJ 45 to DB 9 pinout information for the interconnections between the terminal server and a CDE Interface signal ground 4 GND Interface signal ground 5 GND Receive Data input 6 In RXD Ready to send output 7 Out RTS Data Set Ready input 8 In DSR Clear to Send input...

Страница 193: ...ernet Connector Pin Assignments The Ethernet connector is an 8 pin modular RJ 45 connector Table B 4 through Table B 6 list the Ethernet connector pin assignments White Purple Table B 3 RJ 45 Connector to DB 9 Pinout Signal Name Function RJ 45 Pin RJ 45 DB 9 Pin Signal Name Function 192621 1 2 3 4 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial connector 4 Two port US...

Страница 194: ...e B 5 Ethernet Connector Pin Assignments for T568B RJ 45 Pin Wire Color T568B Wire Diagram T568B 10BASE T 100BASE T 1000BASE T Signal 1 White Orange Transmit BI_DA 2 Orange Transmit BI_DA 3 White Green Receive BI_DB 4 Blue Unused BI_DC 5 White Blue Unused BI_DC 6 Green Receive BI_DB 7 White Brown Unused BI_DD 8 Brown Unused BI_DD Table B 4 Ethernet Connector Pin Assignments for T568A RJ 45 Pin Wir...

Страница 195: ...gory 3 4 or 5 unshielded twisted pair UTP cable to the RJ 45 connector on the back of the device Note The 100BASE TX 1000BASE TX Ethernet standard requires that the cabling in the network be Category 5 or higher Figure B 3 shows the pin number assignments for the Ethernet RJ 45 port Figure B 3 RJ 45 Ethernet Port Connector Fiber Connector Type The fiber connector type used to connect to the SE dua...

Страница 196: ... show the pin assignments for the cable connection for an RS 232 null modem RJ 45 straight through cable and RJ 45 crossover cable respectively Figure B 4 Pin Assignments for RS 232 Null Modem Figure B 5 Pin Assignments and Wiring for an RJ 45 Straight Through Cable RXD TXD GND DB 9 Female End view 5 1 9 6 DB 9 Female 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 TO HOST COMPUTER 211777 End view 5 1 9 6 211...

Страница 197: ...5 Hardware Installation Guide Appendix B Connector Pin Assignments Cable Pin Assignments Figure B 6 Pin Assignments and Wiring for an RJ 45 Crossover Cable 211779 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Brown White Brown White Blue White Green White Orange Orange Blue Green ...

Страница 198: ...B 8 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix B Connector Pin Assignments Cable Pin Assignments ...

Страница 199: ...ternative to the standard power cords Note Only the approved power cords or jumper power cords provided with the server are supported Table C 1 lists the power cords for the server power supplies Table C 1 Supported Power Cords for the Server Description Length Power Cord Reference Illustration Feet Meters SFS 250V 10A AR Power Cord 250 VAC 10 A IRAM 2073 Plug Argentina 8 2 2 5 Figure C 1 CAB 9K10...

Страница 200: ... Cord 250 VAC 13 A NEMA 6 15 Plug North America 8 2 2 5 Figure C 11 CAB 9K12A NA Power cord 125 VAC 13 A NEMA 5 15 Plug North America 8 2 2 5 Figure C 12 CAB C13 CBN Cabinet Jumper Power Cord 250 VAC 10 A C13 C14 Connectors 2 2 0 68 Figure C 13 CAB C13 C14 2M Cabinet Jumper Power Cord 250 VAC 10 A C13 C14 Connectors 6 6 2 0 Figure C 14 CAB C13 C14 AC Cabinet Jumper Power Cord 250 VAC 10 A C13 C14 ...

Страница 201: ...rations See Figure C 1 through Figure C 15 Figure C 1 SFS 250V 10A AR Figure C 2 CAB 9K10A AU Figure C 3 SFS 250V 10A CN 186571 2500 mm Cordset rating 10 A 250 500 V MAX Length 8 2 ft Plug EL 219 IRAM 2073 Connector EL 701 IEC60320 C13 Plug EL 206 A S 3112 2000 Cordset rating 10 A 250 V 500V Length 2500mm 186581 Connector EL 701C IEC 60320 C15 Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB200...

Страница 202: ...d Plugs Figure C 4 CAB 9K10A EU Figure C 5 SFS 250V 10A ID Figure C 6 SFS 250V 10A IS Connector VSCC15 Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug M2511 186576 OVE Cordset rating 16A 250V 2500mm Plug EL 208 187490 Connector EL 701 Cordset rating 10A 250V 500V MAX 2500 mm Plug EL 212 SI 32 186574 Connector EL 701B IEC60320 C13 EL 212 16A 250V ...

Страница 203: ...AB 9K10A IT Figure C 8 CAB 9K10A SW Figure C 9 CAB 9K10A UK Plug I 3G CEI 23 16 Connector C15M EN60320 C15 Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186575 Plug MP232 R Cordset rating 10 A 250 V Length 8 ft 2 in 2 5 m 186578 Connector IEC 60320 C15 Plug Cordset rating 10 A 250 V 500 V MAX Length 2500mm 186580 Connector EL 701C EN 60320 C15 EL 210 BS 1363A 13 AMP fuse ...

Страница 204: ...s Figure C 10 CAB AC 250V 13A Figure C 11 CAB N5K6A NA Figure C 12 CAB 9K12A NA Cordset rating 13A 250V 6 6 feet 79 2m Plug EL312MoldedTwistlock NEMA L6 20 186568 Connector EL 701 IEC60320 C13 Cordset rating 10 A 250 V Length 8 2 ft 186570 Plug NEMA 6 15P Connector IEC60320 C13 Connector IEC60320 C15 Cordset rating 13A 125V 8 2 feet 2 5m Plug NEMA 5 15P 192260 ...

Страница 205: ...ds and Plugs Figure C 13 CAB C13 CBN Jumper Power Cord 0 68 m Figure C 14 CAB C13 C14 2M Jumper Power Cord 2 m Figure C 15 CAB C13 C14 AC Jumper Power Cord 3 m Cordset rating 10A 250V 686mm Plug SS10A 186569 Connector HS10S Cordset rating 10A 250V 2 0 m Plug SS10A 336014 Connector HS10S Cordset rating 10A 250V 3 0 m Plug SS10A 336013 Connector HS10S ...

Страница 206: ...205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix C Power Cord Specifications Supported Power Cords and Plugs Figure C 16 CAB JPN 3PIN Power Cord 3PIN Japan Figure C 17 CAB AC L620 C13 AC Power Cord NEMA L6 20 C13 2 m ...

Страница 207: ...nt Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix C Power Cord Specifications Supported Power Cords and Plugs Figure C 18 CAB 250V 10A CN AC Power Cord Figure C 19 CAB 250V 10A BR ...

Страница 208: ...C 10 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix C Power Cord Specifications Supported Power Cords and Plugs ...

Страница 209: ...80 For the latest information on using the CIMC for troubleshooting see Cisco UCS C Series Servers Integrated Management Controller CLI Configuration Guide Release 2 0 and Cisco UCS C Series Servers Integrated Management Controller GUI Configuration Guide Release 2 0 Troubleshooting Tips This session provides common troubleshooting tips on CDE280 service engine Obtaining Show Tech Support to TAC P...

Страница 210: ...port Technical Support Data dialog box complete these fields TFTP Server IP Address field The IP address of the TFTP server on which the support data file should be stored Path and Filename field The file name in which the support data should be stored on the server When you enter this name include the relative path for the file from the top of the TFTP tree to the desired location Step 5 Click Ex...

Страница 211: ...2 168 1 1 SanDiego cimc tech support set path techsupport showtech SanDiego cimc tech support commit SanDiego cimc tech support start Following are the explanations of some of the key fields within the showtech var Contains detailed logs and status of all monitored services It also contains services information files such as the configuration of SOL and IPMI sensor alarms var log This contains the...

Страница 212: ...t Log Events To display the System Event Log SEL events do the following Step 1 In the Navigation pane click the Server tab Step 2 From the Server tab click System Event Log Step 3 Review the following information for each system event in the log Step 4 Optional From the Entries Per Page drop down list select the number of system events to display on each page Step 5 Optional Click Newer and Older...

Страница 213: ...click the Server tab Step 2 From the Server tab click Sensors Step 3 View various sensors by clicking the desired sensor Figure D 4 Sensors Display of CIMC Log To display the CIMC log do the following Step 1 In the Navigation pane click the Admin tab Step 2 From the Admin tab click CIMC Log Step 3 From the Entries Per Page drop down list select the number of CIMC events to display on each page ...

Страница 214: ...Mount Server do the following Step 1 Check that the AC power cord is ok Step 2 Failure in Power Supply Unit If the Server Host does not power up do the following Step 1 Check front I O board connection Step 2 Check Power Sequencer fault LEDs Step 3 Power Supply unit failure PS Failure LED blinking If the Server powers on with no video do the following Step 1 Check that the front I O dongle is prop...

Страница 215: ...fy Resets are good Common Troubleshooting Scenarios BMC BMC booted Look for Blade health LED to come on which indicates that the BMC has started Step 1 Check that the Standby power rails are ok Step 2 Check that the BMC bios is not corrupt Step 3 Check that the BMC clock is ok Step 4 Check that standby power is ok and resets are valid If the BMC Ethernet cannot communicate do the following Step 1 ...

Страница 216: ...Tips Troubleshooting Tips Figure D 6 Attaching the Ethernet Cable Step 2 Power on the server and press F8 when the CIMC configuration screen appears Step 3 Configure the device with the options shown below Enter your IP subnet mask and gateway addresses Press the Space Bar to apply the new IP configuration Figure D 7 Configuring the CIMCIP ...

Страница 217: ... Ping the IP address associated with the CIMC port Step 5 After verifying the CIMC interface is reachable verify that the CIMC Web Interface is available by pointing your Web browser to its IP address https CIMC IP Step 6 Enter admin as the username and the default password as password Figure D 8 CIMC Main Webpage Connecting to the console To connect to the console do the following Step 1 Enter th...

Страница 218: ...tent Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix D CDE280 and CDE285 Troubleshooting Tips Troubleshooting Tips Step 2 Enter the following command C240 FCH1852V20Y connect host ...

Страница 219: ...e the physical drive status of the new disks from JBOD to Online and to update the virtual drive status perform the following steps Step 1 Log into the UCS Management controller Step 2 Click the Server tab Step 3 Choose Summary Launch KVM Console to launch the Console The KVM Console triggers the Java Application which is already installed in the PC and the Opening viewer popup window appears Step...

Страница 220: ...guration utility is loaded and the Virtual Drive Management window displays the No Configuration Present message under Cisco 12G SAS Modular Raid Bus 0x04 Dev 0x00 All the 24 new disks that are added are listed under Controller Figure E 2 Loading MegaRAID Configuration Utility Step 10 Select Cisco 12G SAS Modular Raid Bus 0x04 Dev 0x00 and press F2 to change the disk status from JBOD to Online Ste...

Страница 221: ...tallation Guide Appendix E Configuring VDS IS CDE280 Disks Changing the Disk Status Using KVM Console Figure E 3 Make Unconfigured Good Step 12 Select all the JBOD disks to change the status to Unconfigured Good Note You can use the Space bar to select all the Disks in JBOD state ...

Страница 222: ...sole Figure E 4 Selecting all the Disks Step 13 Select OK and press Enter On successful conversion you can view all the disks displayed under Unconfigured Drives in the Virtual Drive Management VD Mgmt window Step 14 Press Ctrl N key combination to go to Physical Drive Management PD Mgmt window You can view all the disks state as Unconfigured Good in the PD Management window ...

Страница 223: ...hanging the Disk Status Using KVM Console Figure E 5 Physical Drive Management Step 15 To verify the physical status of the disk choose Storage Cisco 12G SAS Modular Raid Controller SLOT HBA Physical Drive Info from the CIMC Console You can view that the physical drive status is changed as Unconfigured Good Figure E 6 Physical Drive Info ...

Страница 224: ...atus of the Virtual Drive Info from the KVM Console select Cisco 12G SAS Modular Raid Bus 0x04 Dev 0x00 in the Virtual Drive Management window and press F2 Step 17 Select Create Virtual Drive from the drop down list and press Enter Figure E 7 Creating Virtual Device Step 18 Select a single disk using Spacebar to create a Virtual Drive under the Virtual Drive Management window as shown in Figure E ...

Страница 225: ...ep 19 Select OK The confirmation popup window appears Select OK and view the Virtual Drive created using the selected disk Step 20 Repeat the procedure from step 16 to step 19 for creating virtual drives with the entire unconfigured drives On successful creation of the virtual drives for each disk you can view 24 Device Groups and 24 Virtual Drives under the Controller information Figure E 9 Addin...

Страница 226: ...E280 Disks Changing the Disk Status Using KVM Console Step 21 To verify the status of the virtual drive status choose Storage Cisco 12G SAS Modular Raid Controller SLOT HBA Virtual Drive Info The Virtual Drives area displays the following status Status Optimal Health Good RAID Level RAID 0 Figure E 10 Virtual Drive Info Status ...

Страница 227: ...le Step 2 Choose Storage Cisco 12G SAS Modular Raid Controller SLOT HBA Physical Drive Info Step 3 To change the physical drive status select the disks that are in JBOD state and click Set State as Unconfigured Good radio button Figure E 11 Changing the Physical Drive Status A warning message is displayed Click OK to change the status of the physical drive Step 4 To verify the status of the physic...

Страница 228: ...Using CIMC Console Figure E 12 Status changed in Physical Drive Info Step 5 Repeat the step 3 for all the Individual JBOD Disks till the status of all the disks are changed to Unconfigured Good Figure E 13 Status of all Disks in Physical Drive Info Step 6 Click the Controller Info tab and click the Create Virtual Drive from Unused Physical Drives radio button ...

Страница 229: ...Guide Appendix E Configuring VDS IS CDE280 Disks Changing Drive Status Using CIMC Console Figure E 14 Creating Virtual Drive from Unused Physical Drives Step 7 Select the Disk to be added to the Device Group and click the Figure E 15 Selecting the Disk Step 8 Click the Create Virtual Drive ...

Страница 230: ...Status Using CIMC Console Figure E 16 Creating Virtual Drive from Unused Physical Drives Step 9 To verify the status of the disks for which the Device Group is created choose Storage Cisco 12G SAS Modular Raid Controller SLOT HBA Physical Drive Info You can view the Physical Drive status is changed as Online Figure E 17 Verifying the Status of the Disks ...

Страница 231: ...10 To verify the status of the Virtual Drive choose Storage Cisco 12G SAS Modular Raid Controller SLOT HBA Virtual Drive Info The status of a single disk appears as follows Status Optimal Health Good RAID Level RAID 0 Figure E 18 Status of a Single disk in Virtual drive Info Page Step 11 Repeat the procedure from step 6 to step 8 for all the disks that are marked as Unconfigured Good ...

Страница 232: ...sco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix E Configuring VDS IS CDE280 Disks Changing Drive Status Using CIMC Console Figure E 19 Physical Drive Info Page ...

Страница 233: ...in tab and choose the Firmware Management to view the existing version of the CIMC Firmware and the BIOS Firmware Step 3 Click the Server tab To upgrade the firmware and BIOS perform the following steps a Choose Summary Launch KVM Console to launch the Console b In the Opening viewer popup window select the Open with drop down list choose Java TM Web Start Launcher and click OK c Click Continue in...

Страница 234: ...u must ensure that you have already downloaded a ISO image before upgrading h In the Virtual Media popup window click Browse and select the required ISO image i Click Open Note If user upgrade the UCS CIMC and BIOS to 3 0 Version and try for VDSIS ISO to rescue or manufacturing the CDE 280 device which will fail with import export utility To avoid this failure the user needs to run and enable Powe...

Страница 235: ... Upgrade Figure F 1 Selecting ISO Image j Click Map Device You can view a check mark before the ISO File Mapped to CD DVD in the KVM Console Figure F 2 Mapping Device Step 4 Reboot the server a Choose Power Power Cycle Systems cold boot to reboot the server b Click Yes to continue to execute a server control action Device gets restarted automatically c Press F6 for the Boot Menu Options as shown i...

Страница 236: ... Guide Appendix F VDS IS and VQE CDE280 and CDE285 CIMC BIOS Firmware VDS IS and VQE CDE 280 CIMC Firmware and BIOS Firmware Upgrade Boot Menu Options Figure F 3 Boot Menu Options You can view the Entering Boot Selection Menu as shown in Figure F 4 Figure F 4 Entering Boot Selection Menu ...

Страница 237: ...IMC Firmware and BIOS Firmware Upgrade Step 5 Choose Cisco vKVM Mapped vDVD1 22 option from the Please select boot device popup window by navigating using the down arrow key Figure F 5 Selecting Boot Device On successful selection ISO image will be loaded and the Cisco UCS Host Upgrade Utility will be loaded after some time as shown in Figure F 6 Figure F 6 Loading Cisco ISO Image ...

Страница 238: ...IMC Firmware and BIOS Firmware Upgrade Note The upgrade may take approximately 10 to 20 minutes Cisco UCS Host Upgrade Utility launches with the latest version Figure F 7 Cisco UCS Host Upgrade Utility Step 6 Click I Agree in the End User License Agreement Step 7 Click Update after you select the required components Step 8 Click Update All if you want to update all the components ...

Страница 239: ...0 and CDE285 CIMC BIOS Firmware VDS IS and VQE CDE 280 CIMC Firmware and BIOS Firmware Upgrade Figure F 8 Updating Components Step 9 Click Yes in the confirmation popup window to update firmware on all the components Figure F 9 Updating Firmware for the components Step 10 Click Yes to proceed with the firmware update Step 11 ...

Страница 240: ...0 CIMC Firmware and BIOS Firmware Upgrade Figure F 10 Updating Firmware On successful firmware update the status changes to the following SCHEDULED Schedules the process for the selected components IN PROGRESS Displays the progress of the scheduled process SKIPPED Skips the process if both the versions are same PASS Process gets passed once the component is successfully updated ...

Страница 241: ...d VQE CDE280 and CDE285 CIMC BIOS Firmware VDS IS and VQE CDE 280 CIMC Firmware and BIOS Firmware Upgrade Figure F 11 Scheduled Status for the Selected Components Figure F 12 Status of the Selected Components Step 12 Click Exit after all the components are updated Click Yes on the confirmation popup window to exit ...

Страница 242: ...Step 13 Choose Virtual Media ISO file mapped to CD DVD to unmap the ISO file mapped to CD DVD Step 14 Click Yes to unmap the drive request Figure F 14 Unmap the Drive Request Step 15 Choose Power Power Cycle Systems cold boot to reboot the server Step 16 After Rebooting the server log into the UCS Management controller Click the Admin tab and choose the Firmware Management to view the updated curr...

Страница 243: ...Figure F 15 Upgraded to Latest UCS Firmware and BIOS VDS IS and VQE CDE280 CIMC Firmware and BIOS Firmware Downgrade Step 1 Log into the Cisco UCS Management controller After you upgrade the CIMC and BIOS Firmware to higher version the previous version will become the backup version Step 2 Choose Admin Firmware Management Activate BIOS Firmware Note You will receive an error message as displayed i...

Страница 244: ...C Firmware and BIOS Firmware Upgrade Figure F 16 Power Off the Server To Power Off the server follow the steps a Click the icon to Power Off the Server and b Click Activate BIOS firmware to activate the BIOS Firmware Step 3 Select the Firmware version to downgrade and Click Activate Firmware Note By default the backup version of the firmware image remains selected in the popup window ...

Страница 245: ... VQE CDE 280 CIMC Firmware and BIOS Firmware Upgrade Figure F 17 Activating BIOS firmware Step 4 While you perform a refresh BIOS Firmware status changes to Write Host Flash On successful completion of downgrade the backup version becomes the running version Figure F 18 Downgrading BIOS Firmware Step 5 Click Activate Cisco IMC Firmware to load the Backup CIMC Firmware ...

Страница 246: ... By default the backup version of the CIMC Firmware remains selected in the popup window Step 6 Click Activate Firmware Figure F 19 Activating Cisco IMC Firmware Note The Cisco IMC is restarted and is not reachable You must enter the new URL in the browser location bar if the IP address or the HTTP ports have changed On successful completion the backup versions of CIMC Firmware and BIOS Firmware b...

Страница 247: ...IS and VQE CDE280 and CDE285 CIMC BIOS Firmware OMD CDE285 CIMC Firmware and BIOS Firmware Upgrade Figure F 20 Downgraded to previous version of CIMC Firmware OMD CDE285 CIMC Firmware and BIOS Firmware Upgrade For CDE285 CIMC and BIOS firmware upgrade see Cisco UCS C240 M4 Server Installation and Service Guide ...

Страница 248: ...6 Cisco Content Delivery Engine 205 220 250 280 285 420 460 475 Hardware Installation Guide Appendix F VDS IS and VQE CDE280 and CDE285 CIMC BIOS Firmware OMD CDE285 CIMC Firmware and BIOS Firmware Upgrade ...

Отзывы: