2-20
Administrator’s Guide for Cisco IPVC 3521 BRI Gateway, Cisco IPVC 3526 PRI Gateway, and Cisco IPVC 3540 PRI Gateway
OL-7995-01
Chapter 2 Installing the Cisco IPVC 3500 Series Gateway
Configuring Cisco IPVC 3544 Chassis Parameters
Step 4
In the
SNMP Read community
and
Write community
fields, enter default strings used to enable SNMP
communication between the gateway and a external application.
Step 5
On the toolbar, click
Upload
.
Configuring Cisco IPVC 3544 Chassis Parameters
If your Cisco IPVC 3540 PRI Gateway module is installed in the top slot of the
Cisco IPVC 3544 chassis, then the module also performs PCI bus functions for the chassis. In the
Gateway interface, you can use the System section to monitor chassis functions remotely.
One of the functions the chassis performs is to monitor ambient temperature. You can set temperature
thresholds in the System section. The chassis uses these thresholds to trigger a warning that the ambient
temperature exceeds specification and when the temperature has returned to five degrees below the
warning threshold.
Related Topics
•
Viewing the System Section, page 2-20
•
Setting Cisco IPVC 3544 Chassis Temperature Thresholds, page 2-22
•
Refreshing the System Section, page 2-22
Viewing the System Section
You can view the System section by selecting it in the Gateway interface.
Procedure
Step 1
On the sidebar, click
System
.
Table 2-4
lists the elements that appear in the System section.