3-39
Administrator’s Guide for Cisco IPVC 3521 BRI Gateway, Cisco IPVC 3526 PRI Gateway, and Cisco IPVC 3540 PRI Gateway
OL-7995-01
Chapter 3 Configuring the Cisco IPVC 3500 Series Gateway
Configuring Gateway Settings
Note
In European networks, Layer 1 is usually only activated during a call. In such a system, Layer 1
line hunting is not effective and should not be enabled. However, when the gateway BRI port is
connected to a private branch exchange (PBX,) for some PBX, Layer 1 always activates.
Step 17
Select the
Enable static TEI
check box to configure a static TEI. TEI values are supplied by the telecom
company. If you select this option, perform step 17. Otherwise, skip to step 18.
Note
You can only configure this setting if you select
5ESS PTP
or
ETSI PTP
in the
Signaling
Protocol
field of the Physical Interface section.
Step 18
In the TEI Value (0-63) field, enter a value from 0 to 63 for this BRI line.
Step 19
Click
OK
to upload your changes to the gateway database and close the
Advanced
dialog box.
Configuring PRI Port Physical Interface Settings
Note
This section applies only to the Cisco IPVC 3500 PRI Gateways.
In the Physical Interface section of the PRI Port tabs, you can configure the physical line properties of
the specified PRI port.
Procedure
Step 1
In the Gateway interface, on the sidebar, click
Gateway
(if not already selected).
Step 2
Click the applicable
PRI Port
tab.
Step 3
Click the
Physical Interface
button.
Step 4
Select the
Same as Port
check box if you want to duplicate physical interface settings from another PRI
port that you choose from the field. When selected, you cannot modify any settings in this section. This
option is not available in gateways that only support one PRI port.
Step 5
In the
Interface
field, choose the line interface:
T1
or
E1
.
Step 6
In the
Country
field, choose the nation where the ISDN service is installed.
Step 7
In the
Signaling protocol
field, choose the signaling protocol used to setup and tear down the calls
through the signaling (D) channel. Depending on the interface used, different signaling protocols are
available.
Step 8
In the
Network access
field, choose the gateway national access type:
TE
(Terminal Equipment) or
NT
(Network Terminator) device.
Step 9
In the
Clock source
field, choose the gateway clock source:
•
Master
(the gateway provides the clock signal)
•
Slave
(the gateway receives the clock signal)
Step 10
In the
Line Build Out
field, choose
Long Haul
or
Short Haul
.