Table 16: CirPower Hyb state message description�
Message
Description
Calibration
Performing sensors self-calibration
Configuration
Setting up internal components.
Starting
Performing start-up sequence and connection.
Stopped
Inverter stopped.
Grid mode starting
Inverter working connected to grid.
Off-grid mode star-
ting
Inverter working off-grid.
Daily calibration
Daily calibration of the leakage detector.
Alarm
There is an alarm go to alarm screen (see
” 8.4.- ALARMS AND
WARNINGS REGISTER”
).
8�1�2�- kEYS
,
,
The CirPower Hyb main screen may show these keys:
START
, press to start the inverter.
STOP
, touching this key stops the power conversion in the device. If there is no alarm
or warning message, the
CirPower Hyb
remains connected to the grid, and the
START
key is
shown.
After 30 minutes of pressing
STOP
key, the
CirPower Hyb
goes into standy mode. Only a man-
ual reset can wake up the device again. See
“7.1.8.- STANDBY MODES”
The
STOP
key is shown when the device is powered on.
REARM
, is only shown when the inverter is at alarm state.
If the conditions that caused the alarm have disappeared, it allows the user to restart manually
the inverter. The key is not shown once the inverter is restarted.
Note:
When the error disappears, the
CirPower Hyb
rearms automatically after 3 minutes. A
maximum of 4 automatic rearms during an hour is allowed. After that, only manual rearms can
be implemented.