Maximum value :
250 V.
9�2�1�2�- Max Vdc MPPT sweep
Maximum solar panel voltage of the MPPT range.
To modify the value, touch the value, the keypad appears (
Figure 83
), and the new value can
be typed in.
Minimum value :
350 V.
Maximum value :
650 V.
9�2�1�3�- MPPT sweeping freq
This parameter sets the time period between MPPT sweeping the whole MPPT range
To modify the value, touch the value, the keypad appears (
Figure 83
), and the new value can
be typed in.
Minimum value :
0 minute.
Maximum value :
180 minutes.
9�2�2�-PV
In this tab are configured the solar panel parameters.
Figure 85: Basic setup (PV)
9�2�2�1�- Min injection voltage
Minimum solar panel voltage required to start injecting into the grid.
To modify the value, touch the value, the keypad appears (
Figure 83
), and the new value can
be typed in.
Minimum value :
170 V.
Maximum value :
250 V.
86
CirPower Hyb 4k-48
Instruction Manual