CI Systems
SR-800R
4. Set the
Radiometric Offset
(active only in the Differential Mode; a compensation
of temperature deviations, resulting from ambient conditions:
NOTE
In addition, the Radiometric Offset is active only when the
selected target temperature offset value is Zero, see Section
3.2.3.6.1.2
:
Target Setup
.
a. Select
the
On
checkbox to enable the
Radiometric Offset
settings.
b. Set the offset by using the
up/down arrows (0.001
°
resolution)
OR
press
the Radiometric Offset numeric-edit field
to open the floating Keypad
and enter the required offset by pressing the desired number keys, and then
press
. The
R
letter is displayed in the main window, next to the
∆
T
sign -
.
To close and return to the last opened window (the
Menu Window
) press
. To
close and return to the Main window press
.
605-7040
Operation
Manual
Rev D
3-15
June 2013