King Edge
3024-016c
C-13
Program Adjustments (CHI)
NOTE:
Only CHI adjustments
are STATION program specific.
All others are global.
These adjustments apply specifically to the
currently running program. If adjustment mode
was entered with FEEDER OFF shown in the
display, changing any of these settings will have
no effect.
These settings can be individually adjusted:
FAST
LSP
TORQ
AIR
GAP
PACE (only works if pacing lights
included with machine. If no pacing
lights, it reads PMO and cannot be
changed.)
•
•
•
•
•
•
CHI ADJUSTMENTS
Adjustment
Function
Range
(Increment)
Low Range
Select
High Range
Select
Standard
Setting
FAST
Sets the distance the spread
buffer will operate at high speed,
regardless of the LSP setting.
10” - 95”
(5”)
Machine is
operating
below peak
performance.
Flatwork can be
torn or damaged.
30”
LSP
Sets the lower spreader belt speed
in feet per minute.
200 - 500 FPM
(10FPM)
Laydown erratic.
Flatwork not fully
spread before
laydown.
Excessive wear
on lower spreader
motor/belt system.
310 FPM
TORQ
Sets the length of
time that high torque is ON for the
upper spreader.
.00 - .60 sec
(.04 sec)
NA
Pieces may be
damaged and unit
slows down.
.00 sec
AIR
Duration of each laydown air blast.
.00 - .24 sec
(.04 sec)
Laydown erratic.
Low air pressure.
.24 sec
GAP
Minimum spacing between items
fed.
-10” - +50”
(1”)
Excessive overlap
could lead to
folder problems
Unit will operate
below maximum
efficiency.
+03”
PACE
Sets the feed rate (in pieces-per-
hour) for optional pacing lamp.
240 - 600 PPH
(60 PPH)
Green light turns
on below peak
performance.
Green light will
not turn on.
450 PPH
When CHI is chosen from the SELECT
ADJUSTMENT menu, the following displays:
FAST=10” LSP290 TORQ.08S
AIR.16S GAP-07” PACE=420
It is important to use care with the FAST
setting. Used properly, it can increase efficiency
of the unit by increasing throughput.
However, the FAST setting overrides the LSP
setting. Therefore, it if set too high, flatwork
can be damaged or torn by excessive spreading
speed/force.
It generally should be set so that it is 15”
smaller that the smallest piece that will be
processed.
Also, note that the PACE setting only has
meaning if the unit is equipped with the optional
pacing light.
Refer to the table below for information about
each available function to use as a guide in
making adjustments.
Содержание King Edge
Страница 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Страница 66: ......
Страница 122: ......
Страница 182: ......
Страница 183: ...King Edge 3024 016c C 1 King Edge Spreader Feeder CHI PANEL OPERATION KING EDGE TYPE 00 04 PROGRAMS...
Страница 200: ......
Страница 202: ......
Страница 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Страница 218: ...16 PL 3038 008M King Edge Drive Detail Left 23 18 5 17 20 1 3 19 2 25 24 22 21 4 15 7 6 16 16 8 9 10 14 13 12 11...
Страница 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Страница 260: ...2...
Страница 262: ...4...
Страница 264: ...6...
Страница 266: ...8 C...
Страница 268: ...10...
Страница 270: ...12...
Страница 272: ...14...
Страница 274: ...16...
Страница 276: ...18...
Страница 277: ...19...
Страница 278: ...20...
Страница 280: ...22...
Страница 281: ...23...
Страница 282: ...24...
Страница 284: ...Skyline S1 S20 Installation...
Страница 285: ......
Страница 286: ...Skyline S1 S20 Installation...
Страница 288: ......
Страница 290: ......