6.8 Sanitising the dispenser
CAUTION
SANITIZATION
Before sanitizing the machine, carefully read the instructions given by the sanitization product
manufacturer and put on all the necessary personal protective equipment (gloves, masks, etc.).
Ensure that the premises are well ventilated.
The sanitization of the product lines must only be carried out by specialized technical service
personnel.
The dispenser should be sanitized completely every 4 months; contact the retailer or an
Authorized Service Centre for this purpose.
Sanitization is also required after long periods of non-use.
After short periods of non-use, you are advised to dispense a few litres of water before using the machine.
You must use suitable products (detergent and sanitizing solution).
Detergent solution can be prepared mixing 3 gr of liquid dish washing detergent per liter of potable water
(20-40°C temperature).
Sanitizing solution can be prepared mixing 5 gr of 4% sodium hypo chlorite solution (non scented liquid
house hold bleach) per liter of potable water (20-40°C).
CAUTION
After the sanitizing solution has passed through the lines, you must rinse very well with clean
water until every trace of the sanitizing agent is completely eliminated.
Check the pH of the output water is the same as that of the input water (use litmus paper or a
pH meter).
The procedures to follow will differ according to whether the syrup is contained in a steel keg or in a bag-in-
box.
LINES WITH STEEL KEGS
7 -
Remove the cover from the dispensing valves, and turn off the water taps.
8 -
Disconnect the connector (black) from the syrup container, rinse it in clean hot water and connect a
tank containing clean potable water.
9 -
Run clear water through the connector, at the same pressure level as for the syrup.
10 -
Intervene on the lever of the dispensing valve that corresponds to the line you want to sanitize;
dispense until only water comes out of the valve.
11 -
Disconnect the connector from the clean water container and connect a tank containing the detergent
solution described above to syrup circuit at the same pressure level as for the syrup.
12 -
Run the detergent solution through the connector, at the same pressure level as for the syrup.
13 -
Be sure to respect the concentration level according the above information