Installation
36
Rev. 10/17
Brave 30 ES - Brave 60 ES - Brave 90 ES
To make the carbon dioxide connection correctly, proceed as follows:
1 -
Check the pressure reducer adjuster screw is
completely unscrewed.
2 -
Connect the pressure reducer to the cylinder valve
using the gasket provided.
If you are making the connection by means of a high
pressure tube, make sure the correct gaskets are fitted on
both joints. The reducer must be secured to the wall by
means of a suitable wall bracket. Use a suitable spanner
to firmly fix the reducer to the gas cylinder, or the high
pressure tube to the cylinder and pressure reducer, if
installed.
3 -
Insert the tube in the appropriate connection point
on the reducer, then connect it between the pressure
gauge and the CO
2
inlet connection on the machine itself.
Never exceed the pressure of 6.5 bar at the outlet of the reducer in order to prevent compromising the
circuit.
BR0330
CO
2
IN
VENT
VALVE
VENT VALVE
TO THE CARBONATOR
TO THE SYRUPS
HIGH PRESSURE
GAUGE
LOW PRESSURE GAUGE
WITH FULL SCALE
6 bar (87 psi - 0,6 MPa)
LOW PRESSURE GAUGE
WITH FULL SCALE
10 bar (145 psi - 1 MPa)
BR0340
EXAMPLE OF CO
2
CYLINDER REDUCER CONNECTION