Installation
35
Brave 30 ES- Brave 60 ES - Brave 90 ES
4.5.6 Carbon dioxide (CO
2
) connection
To facilitate the connections, the inlets and outlets are identified by special adhesives.
DANGER
CO
2
(CARBON DIOXIDE)
The place where the CO
2
cylinders are stored must always be well ventilated, with an air flow
inlet and outlet. Great care must be taken to prevent CO
2
leaks throughout the system, including
the gas cylinders. If a CO
2
leak is suspected, especially in a small area, ventilate the
contaminated area at once. People exposed to a high concentration of CO
2
will experience
trembling, swiftly followed by loss of consciousness and suffocation.
DANGER
GAS CYLINDER POSITION
To prevent damage or hazards, always place the CO
2
cylinder vertical, against a wall, securing
it with a chain fixed to a bracket.
Do not expose the gas cylinder to heat sources or excessively low temperatures.
Only super-dry food grade CO
2
should be used.
Before connecting the pressure regulator to the cylinder, check that there is no dirt on the valve. If so,
remove it carefully.
There are different types of CO
2
cylinders on the market.
Always obtain a pressure reducer suitable for the type of valve on the cylinder.
BR00171
BR0210
CO
2
INTAKE
IN/OUT ADHESIVE