Description of the machine
24
Rev. 10/17
Brave 30 ES - Brave 60 ES - Brave 90 ES
Summary table
Display language
The display is factory-programmed in English (EN).
You can visualise the display in Italian by altering the control unit programming parameters. Contact Celli for
further details.
ALARM / ANOMALY
MESSAGE ON THE DISPLAY
RESET
Compressor delivery tube T° too
high
ALTA TEMP COMPR
HIGH TEMP COMPR
Automatic
Carbonation pump body T° too
high
ALTA T POMP CARB
HIGH T CARB PUMP
Automatic
Soda recirculation T° too high
ALTA T POMP RICS
HIGH T REC SODA P
Automatic
Tank water T° too high
ALTA T H2O VASCA
HIGH T H
2
O BATH
Automatic
Wet anti-flooding probe
ALLAGAMENTO
WATER LEAKAGE
RESET button
Time-out for inlet of water into
machine (10 min)
ING H
2
O TIME OUT
IN H
2
O TIME OUT
RESET button
Inlet water pressure too low
PR H
2
O ING BASSA
H
2
O IN PR LOW
Automatic
Inlet CO
2
pressure too low
PR CO
2
ING BASSA
CO
2
IN PR LOW
Automatic
Carbonation pump pressure too
low
PR P CARB BASSA
CARB P LOW PR
Automatic
Time-out for compressor
operation (24 h)
COMPR TIME OUT
COMPR TIME OUT
RESET button
Time-out for carbonation pump
(4 min)
P CARB TIME OUT
CARB P TIME OUT
RESET button
Time-out for still water pump
(4 min)
P A/P TIME OUT
PL WT P TIME OUT
RESET button
Low CO
2
BULK tank level
LIV BULK BASSO
CO
2
BULK LEV LOW
Automatic
Inadequate mains voltage
PROTEZ VOLTAGGIO
VOLTAGE PROTECT
Automatic