Description of the machine
19
Brave 30 ES- Brave 60 ES - Brave 90 ES
Still water, with pressure switch and solenoid
valve
The machines that adopt this technical solution use the
same pump for the carbonator and for the still water (see
the electric and hydraulic diagrams for further details).
When the still water dispensing valve on the tower is
activated, a pressure switch (
P
) activates the pump (
A
);
the water passes through the cooling coil (
B
), the check
valve (
C
), and the pressure reducer (
D
). The solenoid
valve (
E
) remains closed.
When soda needs to be dispensed, the energy saving
control unit (
F
) activates the pump (
A
) and opens the
solenoid valve (
E
). The water passes through the cooling
coil (
B
), the solenoid valve (
E
) and the double check
valve, and enters the carbonator (
H
).
Inside the carbonator, the water immediately becomes
sparkling. As a result, when it leaves the carbonator it is
soda.
D
BR0360
P
A
B
E
C
H
BR0370
F
BR0361
P