Maintenance
51
Brave 30 ES- Brave 60 ES - Brave 90 ES
15 -
Reconnect the connector to the syrup container, and intervene on the dispensing valve until syrup
begins to come out.
16 -
Turn on the water tap on the dispensing valve again, and replace the cover.
17 -
Check the soda - syrup mix ratio of the valve (chapter ”4.8” pag. 39).
18 -
Repeat these operations for all the syrup lines.
6.9 Cleaning and checking the liquid check valve
CAUTION
LIQUID CHECK VALVE
The carbonator liquid check valve should be inspected after any water supply system failure
(plumbing work, earthquakes, etc.), and at least once a year in normal conditions. If particles
are trapped in the control valve, the CO
2
might flow back into the water supply system.
1 -
Disconnect the machine from the electricity supply.
2 -
Remove the upper panel.
3 -
Shut off the water and CO
2
supplies.
4 -
Disconnect the water coil from the liquid check
valve.
5 -
Remove the liquid check valve (
A
).
6 -
Clean and check the O-rings and every single part,
and in particular check there is no damage to the surface
of the ball. Replace any damaged parts.
7 -
Reassemble the liquid check valve (
A
), taking care
to put it back in its original position.
8 -
Turn on the water and CO
2
supplies.
9 -
Refit the upper panel.
10 -
Reconnect the machine to the electricity supply.
6.10 Cleaning the syrup connectors
1 -
Remove the syrup connectors.
2 -
Immerse them in a mixture of warm water and sanitising solution, then rinse them well.
3 -
Reassemble the syrup connectors.
BR0270
A