CatonCaster HD422 User Manual
Page of
85
107
www.catontechnology.com
July 2020 R1
Title
Description
Name
This column displays the name of the error or condition. This is informational
data: no options can be set here.
Lcation
This column displays the hardware or function that the alarm or event applies to.
This is informational data; no options can be set here.
Log
Checking the box in this column creates an entry in the event log in the case this
error or event is raised. If this box is unchecked this error or event will be hidden
and not logged if raised.
Log Severity
This column is only available in the tab This option allows the user to
set the severity of the error to Info or Error. If Info is selected in the drop down
box the icon will displayed in the event log. If Error is selected the icon
will be displayed in the event log.
Alarm
This column is only available in the tab This option allows the user to
enable or disable this alarm in the Active Alarms log. If checked the alarm will be
displayed in the Active Alarms log if raised. If this box is unchecked this error will
be hidden.
SNMP Trap
This column allows the user to send an SNMP Trap if this alarm is raised. If this
box is checked an SNMP Trap is sent when this alarm is raised. If this box is
unchecked an SNMP is not sent.
Relay
This column allows the user to set a Relay closure if this alarm is raised. If this
box is checked a Relay will be closed. If this box is unchecked a Relay will not be
closed. See Appendix C for pinout.
Relay #
This column allows the user to select which of the three relays available on the
CatonCaster HD422 will be closed when the alarm is raised.
Relay Duration
This column is only available in the tab. This option allows the user to
define the length of time in milliseconds the relay will be closed after the event is
logged. This setting can be configured from 100-1000 milliseconds.