CatonCaster HD422 User Manual
Messages can be manually inserted by clicking the green arrow that is shown when the SCTE 35 section is
expanded as shown below. In a typical operational scenario, the splice insertion will be automated and
triggered using the SNMP MIB.
Page of
49
107
www.catontechnology.com
July 2020 R1
Setting
Range
Description
State
Enabled
Disabled
Enable or Disable SCTE 35 message Insertion
PID
0-8191
PID on which the inserted SCTE 35 messages will be
inserted
Splice Type
Normal
Immediate
Selects whether the SCTE 35 message will be of the
“splice immediate” type (which can trigger an
instantaneous switch downstream) or the normal type
which uses a PTS-based preroll value to time the
insertion.
Pre-Roll (ms)
0-20000
Configured offset prior to splice point
Event ID (Hex)
0-FFFFFFFF
Unique Event ID for the SCTE 35 message
Network Event
Out of Network
Return to Network
Select which network transition signal is used for the
SCTE 35 message
Break Duration
(ms)
0-95443717
Duration in ms of the Out of Network Break
Unique
Program ID
0-65535
Unique program identification within a service
Avail Num
0-255
Authentication for a specific avail in the Unique Program
ID
Avails Expected 0-255
Number of Avails expected in the current viewing event