Event ID Filter
Pass All
Pass Event ID
Pass Event Source
Selects whether all Events will trigger the relay, or only
those with a certain Event ID or Source
Event ID (Hex)
0-FFFFFFFF
Used in “Pass Event ID” mode to filter which SCTE 35
messages that will trigger the relay
Event Source
(Hex)
0-FFFFFFFF
Used in “Pass Event Source” mode to filter which SCTE
35 messages that will trigger the relay
Offset (ms)
-4000ms to 4000ms
Specify an offset for the Trigger
Relay Mode
Pulse
Latch
Specify a mode for the relay. In pulse mode the relay will
fire once on either OON or RTN. In latch mode the relay
will remain energized for the entire break duration
Pulse Event
Out of Network
Return to Network
Select which SCTE 35 splice_insert message triggers
the relay
Pulse Duration
(ms)
10-1000
Select which SCTE 35 splice_insert message triggers
the relay
Latch Timeout
(ms)
1-300
Specify a duration for latch mode. Note: Receiving a
Return to Network message will override the latch
timeout.