4.2.18 Configuring Ancillary Data Options
This menu allows the user to configure processing options relating to ancillary (ANC/VBI) data generation.
Currently it contains options for Source ID and, if the SCTE35 license is enabled, it will also allow the user to
configure the filter mode for SCTE104 messages.
Page of
51
107
www.catontechnology.com
July 2020 R1
State
Enabled
Disabled
Enable or Disable
Asynchronous message insertion
Port
0-65535
Port on which the CatonCaster HD422 will listen for
SCTE 35 messages from the ESAM server
PID
SCTE 35 PID present in TS
PID on which the SCTE 35 messages will be inserted in
the transport stream
Setting
Range
Description
Lookup Mode
Auto
Manual
Setting Lookup Mode to auto will use the service
information from the active stream service information
tables (if source id present). Setting Lookup Mode to
manual will allow the user to input a user defined source
id.
Manual Source
ID
ASCII Characters
User defined Source ID will need to be less than 14
characters
Timeout (sec)
5 – 120 sec
This will define the timeout for automatic extraction.
Filter Mode
Pass All Operations
Pass First Operation
Setting Pass First Operation will filter SCTE 104
messages with multiple OpID’s and only pass the first
OpID of that message.