CatonCaster HD422 User Manual
4.3.10 In-Band Control
The In-Band Control is used to change settings and receive updates from data within a PID in the incoming
TS, as injected by the Sencore CMD 4000 In-band Control Server. The following menu allows the user to
configure the In-Band Control settings. To configure the In-Band Control settings click the
button.
4.3.11 Updating the CatonCaster HD422
4.3.11.1 Applying Software Updates
Updates to the CatonCaster HD422 are performed through the web interface. A software update file is
provided by Caton and then uploaded to the unit. Once uploaded, the software update is applied to the unit.
To upload software updates to the unit click on the
button. The current version and uploaded
version is displayed in the Software Versions section. The CatonCaster HD422 will reboot after a software
update is complete.
Page of
79
107
www.catontechnology.com
July 2020 R1
Action
Range
Description
State
Enabled
Disabled
Enable or Disable sending messages to Syslog
server.
Network
Protocol
UDP
TCP
Select which network protocol used to transmit
to the Syslog server
IP Address
Four decimal octets:
XXX.XXX.XXX.XXX
IP of the Syslog server. 0.0.0.0 and
255.255.255.255 are not permitted
Port
0-65535
Destination port of the Syslog server
Action
Range
Description
State
Enabled
Disabled
Enable or Disable the In-Band Control.
PID
1-90
Sets the unit to look for commands on the PID
that is set.
Group
None
1-128
This setting assigns the unit to a corresponding
Group or No Group.