3.1
S
WITCH MODE
(
EASY
/
NORMAL MODE OF THE PROGRAMMER
)
*Note:
the Master-slave setting can only be changed with all channels in stop status.
On this screen you can switch the mode of operation of the Heatmanager Pro. This has only
influence on the channels that operate as a programmer.
You can select the so-called easy more where a profile only has a ramp up, soak temperature,
soak time, ramp down and end temperature.
Instead of the easy mode, you can select the so-called normal mode where the Heatmanager
Pro programmer works with 7 separate segments. Each segment consists of a ramp and a soak
(so both the ramp part, as well as the soak part, are combined into 1 segment). Please note that
segment 8 is used for channels that are not configured as a programmer, such as slave(s),
remote(s) and channels that are in stopped mode (also when a programmer is in stop, it will be
set to segment 8.
[EASY]
Select the easy mode (ramp up, soak temp & time, ramp down and end
temp)
[NORMAL]
Select the normal mode (max. 7 segments each consisting of a
ramp+soak)
[BACK]
Return to the previous screen
[MAIN MENU]
Return to the main menu