Heat Manager Pro User Manual V1.5 Page 21
2.4
E
DIT HEATING PROFILES
–
NORMAL MODE
When the normal mode is used (settable in the basic settings) the following screen appears:
The profile consists of up to 7 segments.
Each segment consists of a ramp up/down part and a soak part.
[SEGMENT]
Enter a segment number from 1
– 7
Note that when you select a specific segment number, you are editing the set temperature,
ramp, dwelltime and link segment of that specific selected segment.
[SET TEMPERATURE]
Enter a desired set value for the temperature
[RAMP DEGR/HOUR]
Enter a desired heat up/down rate
[DWELLTIME IN MIN]
Enter a desired dwelltime (soaktime) in minutes
[LINK SEGMENT]
Value 0:
don’t continue to a next segment, remain at
set value after soaktime exceeded
Any other value, up to 7, can be set here. After the soaktime is
passed the Heatmanager Pro will continue with the segment set
in link segment.
You can also enter the soaktime in hours+minutes and push the copy to soaktime button for
easy calculation of soaktime in minutes.
When setting the ramp [degrees/hour] to 0, the Heatmanager Pro immediately proceeds to the
set value temperature without performing a ramp up/down.
After all channels have been correctly set, the main menu screen appears.