Heat Manager Pro User Manual V1.5 Page 81
E.5
H
OW TO CHANGE A PROFILE INSIDE A RUNNING PROGRAMMER
?
Push on the white rectangle around the programmer channel that you wish to change.
Easy mode: push the value you wish to modify. Enter the new value and ready.
Normal mode: select the segment you wish to modify in, change the value and push back to go
back to the operation screen.
E.6
H
OW DO
I
CHANGE A RAMP IN A RUNNING PROFILE
?
Push on the white rectangle around the programmer channel that you wish to change.
Easy mode: push the value you wish to modify. Enter the new value and ready.
Normal mode: select the segment you wish to modify in, change the value and push back to go
back to the operation screen.
E.7
T
HE OPERATION SCREEN APPEARS LOCKED
(
LOCK INDICATOR IN RIGHT TOP
)
HOW TO UNLOCK
?
Push for a few seconds on the left bottom of the screen, after a white the lock indicator
disappears and normal operation is possible. You lock it again by pushing a few seconds in the
left bottom corner of the main menu.
E.8
W
RONG MEASUREMENTS
:
DEVIATING TEMPERATURES
The Heatmanager Pro works with thermocouple type K thermocouple input. Use the proper
thermocouple wire. Here is a table with the most common thermocouples used and their proper
extension cable, use the KX values of the table for type K thermocouples.
E.9
W
RONG MEASUREMENTS
:
TEMPERATURE GOES DOWN WHILE HEATING UP
Check the polarity of the thermocouple and cabling, check table of E.8.