Heat Manager Pro User Manual V1.5 Page 32
2.7.1. Export data to USB
Push [EXPORT DATA TO USB] in the data menu (accessible from main-menu) and the follow-
ing screen will appear:
During normal operation, and only when one of its channels is running, the Heatmanager Pro
works with a 4032 value internal battery backup buffer to store up to 4032 temperature meas-
urements. It will delete the oldest value and enter the newest one (first in first out LIFO).
When an USB stick is present in the system the [SAVE TO USB] button will appear. Enter the
desired filenumber (1-65535) in the file number and push [SAVE TO USB]. The Heatmanager
Pro will now write all measured values into a .CSV file. It will be present on the USB device in
the \SAMP01 directory as the entered filH.csv. This file can be imported into Excel or
Openoffice Calc (free downloadable).
Before pushing the [SAVE TO USB] button, you can enter the desired batch information of the
process by pushing the [ENTER BATCH DATA] in the previously shown data menu. When you
push the [SAVE TO USB] button the entered data will be written in a separate .csv file and it will
also appear in the \SAMP01 directory on the USB stick.
[FILE NUMBER]
Enter the desired number that is used as a filename
[SAVE TO USB]
Store the up to 4032 measurements button on USB stick under
the filename entered in file number. This button only appears
when an usb stick is present.