Interface Module Settings
*
Inserting this jumper adds a 120 Ohm termination resistor across the RS-485 RX+ and RX- lines.
**
Inserting this jumper adds a 120 Ohm termination resistor across the CAN Bus.
Jumper
Description
Comments
Default Setting
E4
E5
E10
E2
E3
E6
E7
E8
E9
ROM size select.
1-2 = 256K, 27256 device
2-3 = 512K or 1024K, 27512 or
27010 devices
RS-232C/RS-485 select
RS-485 termination resistor
CAN Bus termination resistor
Circuit common to earth ground connection.
Selects 24 VDC source control or grounded
sink control for digital inputs
12-15.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 24 VDC source control or grounded
sink control for digital inputs
8-11.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 24 VDC source control or grounded
sink control for digital inputs 4-7.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 24 VDC source control or grounded
sink control for digital inputs 0-3.
2-3 = 24 VDC source
1-2 = grounded sink
Factory set. Do not change
unless instructed to do so.
512K
1024K
RS-232C
*
**
Source
Source
Source
Source
2-3
2-3
Out
In
In
2-3
2-3
2-3
2-3
INTERFACE MODULE JUMPER SETTINGS
LN-9400-00-R11 (08/2018)
73 / 96
www.carlisleft.com
MAINTENANCE
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...