CAUTION
!
WA R N I N G
!
WA R N I N G
!
PILOT SIGNAL GUIDELINES
Tubing Size
OD
Fluid Regulator
Type
Typical
Application
Feet
Meters
Feet
Meters
Maximum Length
Minimum Length
1/4"
MVR Two-component 15 4.6 20 15.3
1/4"
DR1
Single-Component 15 4.6 50 30.5
Do not locate the Control Panel near or adjacent
to heat producing equipment such as ovens, high
wattage lamps, steam pipes, etc.
Equipment Mounting
Use the mounting ears supplied to mount the control or
interface enclosure on a wall or building structure. The
anchor system used must be rated to support the specified
weight of the enclosure being mounted (see specifications,
page 13). When properly mounted, the anchor system
shall be capable of withstanding 4 times the rated weight
without causing a hazardous condition.
The Control Enclosure must be located in such
a way that access to the On/Off power switch and
Stop switch is not blocked.
The On/Off switch turns off AC power to the PC
and 24 VDC supply.
The Stop switch interrupts only the 24 VDC.
The AC power input FUSED DISCONNECT
must be located in an accessible area near the
Control Enclosure
If improperly located, certain electrical equip-
ment can become a source of ignition and create a
risk of fire or explosion.
The Control and Interface Enclosures must
be located outside of the Class 1, Division 1 and
2 hazardous locations which are defined for spray
finishing of flammable and/or combustible materials.
Definitions and requirements for classified areas
are found in the National Electrical Code, NFPA-
70, Article 516 and the National Fire Protection
Association (NFPA-33).
LN-9400-00-R11 (08/2018)
18 / 96
www.carlisleft.com
INSTALLATION
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...