NOTE
Refer to Addendum C for complete information
regarding the flow limitations of the DynaFlow
Channel cards.
NOTES:
1. If the output of Gun 2 supplies one or more hand guns,
then Gun 2 should be operated in Manual mode using a
CCV for the Master Channel flow controller.
2. If the output of Gun 2 supplies a single applicator, then an
MVR should be used for the Master Channel flow controller
and Gun 2 should be operated in Auto mode.
3. If the output of Gun 2 supplies multiple appl-icators other
then hand guns, then Gun 2 should be operated in Manual
mode using a CCV for the Master Channel flow controller.
Additional Guns should be configured for each applicator
as shown below to provide automatic flow control for each
applicator.
Gun 3 through 6 =
Master Channel =
Material = Output of Gun 2
(Resin + 2
nd
+ 3
rd
Components)
Flow Controller = DR1
Flow Meter = Gear-Type
Operating Mode = Auto