The following solenoid valves can be controlled by the
sequencer:
Resin/Solvent Air Chop
Resin Solvent
Resin Air
Paint
Dump Valve
Resin Fluid Override
Trigger Solenoid
Catalyst #1
Catalyst #2
Catalyst #3
Catalyst Solvent
Catalyst Override
The following DynaFlow inputs can be controlled by the
sequencer:
DynaFlow Run
DynaFlow Halt
DynaFlow Trigger
DynaFlow Load
DynaFlow Clean
Catalyst Disable
Note that there are too many valves and signals to be
displayed on one screen. Therefore, the operator must
scroll down to see the bottom five items.
Program the time for each step by touching the step du-
ration box under the step to be modified and then push
F1 (Modify) to change it. Then toggle any of the signal or
valve boxes at each step that you wish to have on during
that step and then push the Modify button. The steps will
toggle between Off and On as you continuously hit the
Modify button.
The Hold step is the final step in the sequence (for both
flush and fill). When the sequence completes, the signals
and valves will be held in the condition selected in the hold
step. Keep in mind that when changing from one color to
another, the system performs a flush sequence followed
by a fill sequence so the hold step in the flush sequence
will only occur momentarily.
There are 8 function keys defined while editing flush, load,
and color change sequences:
F1: Modify
– This button brings up a numeric keypad if
cursor is on one of the step duration cells. If cursor is on
one of the valve condition cells, that cell is toggled from
off to on or on to off.
F2: Chop Air Time
– This button allows the user to pro-
gram how long the air valve remains on for each step of
the solvent/air chop timer.
F3: Chop Solvent Time
- This button allows the user to
program how long the solvent valve remains on for each
step of the solvent/air chop timer.
F4: Edit Fill/Flush
– This button opens the screen that
allows viewing and editing of the flush or the fill sequences
(the button changes to fill if the flush sequence is displayed
and to flush if the fill sequence is displayed).
F5: Send to PLC
– This button allows the operator to imme-
diately send the edited sequence to the sequencer (located
in the motor amplifier panel). Note that the sequences are
automatically sent to the sequencer every time a new Job
Number is loaded.
F8: Copy Sequence
– This button allows the operator to
copy sequences from one job to another.
F9: Read In File
– This button allows the operator to
load flush and load sequences from the flash drive of the
touchscreen, a USB memory stick, or to a floppy diskette.
F10: Save To File
– This button allows the operator to
save flush and load sequences to the flash drive of the
touchscreen, a USB memory stick, or to a floppy diskette.
All flush and load sequences for all guns are saved in a
file named: ColorChg.par.
LN-9400-00-R11 (08/2018)
41 / 96
www.carlisleft.com
OPERATION
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...