Channel Module Hardware Specifications (Cont.)
4 Analog Inputs (2 Channels):
Jumper selectable 0-10 VDC (default) or 4-20 ma, op-amp buffered, 10-bit A/D.
Set Point Control #1:
Used for external analog control. When used, offset and full scale need to be set.
This is accomplished through the MAXIMUM FLOW RATE and MINIMUM FLOW
RATE JOB parameters.
Set Point Control #2:
Used for external analog 10-bit A/D control. When used, offset and full scale need
to be set. This is accomplished through the MAXIMUM FLOW RATE and MINIMUM
FLOW RATE JOB parameters.
Spare #1:
Not used presently
Spare #2:
Not used presently
4 Analog Outputs (2 Channels):
Jumper selectable 0-10 VDC (default) or 4-20 ma, op-amp buffered, 12-bit D/A.
Transducer Control #1:
Output to proportional E/P 12-bit D/A controller
Transducer Control #2:
Output to proportional E/P controller
Flow Rate #1:
Flow Rate (scaled between MINIMUM FLOW RATE and MAXIMUM FLOW RATE
JOB parameters)
Flow Rate #2:
Flow Rate (scaled between MINIMUM FLOW RATE and MAXIMUM FLOW RATE
JOB parameters)
4 Frequency Inputs:
From flow meters (reverse flow capable)
Source Signal #1 & #2:
Frequency used to determine flow rate (pulses per volume or weight).
Maximum Frequency = 435 Hz
Minimum Frequency = 1 Hz
(Refer to Addendum C for flow limitations.)
Phase Signal #1 & #2:
State used to determine direction of flow rate, forward or reverse.
PID Control:
Closed loop control based on the Kp, Ki, Kd and deadband JOB parameters. 30ms
PID update time (default), each channel.
Communications
CAN:
Controller Area Network (CAN) High-speed serial communications to Interface Module.
RS-232C Port:
Spare auxiliary communication port.
Power Requirements:
24 VDC at 100 ma typical – each Channel Module
Operating Temperature:
0
o
to 55
o
C
Control Enclosure (A12233)
Dimensions:
610mm H X 610mm W X 410mm D
Weight:
45.5 Kg (100 lbs)
AC Power:
115/230 VAC, 3A 50/60 HZ 1 Phase
Temperature:
5
°
C - 40
°
C
Humidity:
80% to 31
°
C decreasing to 50% at 40
°
C non-condensing
Interface Enclosure (A12182)
Dimensions:
610mm H X 610mm W X 410mm D
Weight:
22.7 Kg (50 lbs)
Temperature:
5°C - 40° C
Humidity:
80% to 31° C decreasing to 50% at 40° C non-condensing
LN-9400-00-R11 (08/2018)
16 / 96
www.carlisleft.com
INTRODUCTION
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...