Displayed Text
Fault Cause
Corrective Action
ERROR CODES
(Cont.)
Code
TROUBLESHOOTING GUIDE
(Cont.)
(Continued On Next Page)
Reverse Flow Limit -
CHANNEL #<>
The amount of reverse flow for the in-
dicated CHANNEL has ex-ceeded the
maximum allowable amount as defined
in the CHANNEL parameter set.
Last digit indicates
CHANNEL #
.
Check the following:
1. That the Reverse Flow value entered in the
JOB # is correct.
2. Flow meter fiber-optic cables are properly
connected and not reversed.
3. Fluid pressures are properly set and stable.
4. All check valves are operating correctly.
5. All fluid lines filled and all valves open.
6. Flow meter is operating properly.
9021
9022
9023
9024
9025
9026
9027
9028
9031
9032
9033
9034
9035
9036
9037
9038
Flow Too Low -
CHANNEL #<>
The flow rate for the indicated CHANNEL
# is too low. Based on the transducer
output. Not issued for a manual GUN,
master CHANNEL.
Last digit indicates
CHANNEL #
.
Check the following:
1. There is fluid in the fluid lines for the
indicated CHANNEL.
2. Fluid pressures are properly set and
stable.
3. The pilot air line to the fluid regulator is
not damaged or leaking.
4. Fluid viscosity is correct for the CHANNEL
pressure and pipe size.
5. The pressure transducer and regulator
are operating properly.
6. Transducer air supply is at least 90 psi.
7. Kp, Ki, and Kd Gains are set correctly
for the indicated CHANNEL.
9041
9042
9043
9044
9045
9046
9047
9048
Flow Too High
The flow rate for the indicated CHANNEL
# is too high. Based on the transducer
output. Not issued for a manual GUN,
master CHANNEL.
Last digit indicates
CHANNEL #
.
Check the following:
1. Fluid regulators - sticking or faulty.
2. Control parameters - gains possibly set
too high.
3. MVR low setting too high.
9071
9072
9073
9074
9075
9076
9077
9078
No Master Flow
Manual mode only. A trigger signal was
received and no fluid flow was detected
through the master chan-nel after the
Blowoff timer had elapsed (if used).
Check the following:
1. There is fluid in the fluid lines for the
indicated CHANNEL.
2. Fluid pressure is OK.
3. The flow meter, pressure trans-ducer,
and regulator are operating properly.
LN-9400-00-R11 (08/2018)
59 / 96
www.carlisleft.com
MAINTENANCE
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...