Selects 24 VDC source control or grounded
sink control for digital inputs 12-15.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 24 VDC source control or grounded
sink control for digital inputs 20-23.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 24 VDC source control or grounded
sink control for digital inputs 16-19.
2-3 = 24 VDC source
1-2 = grounded sink
Selects 0-10 VDC or 4-20 ma operation for
the analog control output #2.
2-3 = 0-10 VDC
1-2 = 4-20 mA
Selects 0-10 VDC or 4-20 ma operation for
the analog output #2.
2-3 = 0-10 VDC
1-2 = 4-20 mA
Selects 0-10 VDC or 4-20 ma operation for
the analog set point input #2.
2-3 = 0-10 VDC
1-2 = 4-20 mA
Selects 0-10 VDC or 4-20 ma operation for
the spare analog input #2.
2-3 = 0-10 VDC
1-2 = 4-20 mA
Inputs effected:
Trigger #2
Gun Mask #2
Transparent/PID #2
Total Hold #1
Inputs effected:
Load Mode #2
Analog Hold #2
External Fault #2
MVR Enable #2
Inputs effected:
Run #2
Halt #2
Total Reset #2
Clean #2
To the E/P transducer #2
Actual flow rate for CHANNEL #2, scaled
by Maximum and Minimum Flow Rate
parameters
Scaled by Maximum and Minimum
Flow Rate
parameters
Source
Source
Source
0-10 VDC
0-10 VDC
0-10 VDC
0-10 VDC
2-3
2-3
2-3
2-3
2-3
2-3
2-3
E3
E1
E2
E6
E7
E5
E4
Jumper
Description
Comments
Default Setting
CHANNEL MODULE P/N: 77206-XX (Obsolete)
DAUGHTER BOARD JUMPER SETTINGS (CHANNEL 2 I/O)
LN-9400-00-R11 (08/2018)
71 / 96
www.carlisleft.com
MAINTENANCE
Содержание Ransburg DynaFlow 77376
Страница 13: ...Figure 1 Block Diagram Return To Contents LN 9400 00 R11 08 2018 13 96 www carlisleft com INTRODUCTION...
Страница 90: ...Fluid Panel Sheet 1 Return To Contents LN 9400 00 R11 08 2018 90 96 www carlisleft com APPENDIX...
Страница 91: ...Fluid Panel Sheet 2 Return To Contents LN 9400 00 R11 08 2018 91 96 www carlisleft com APPENDIX...
Страница 92: ...Fluid Panel Sheet 3 Return To Contents LN 9400 00 R11 08 2018 92 96 www carlisleft com APPENDIX...