Manual release should only be carried out when the motor has stopped
due to blackouts.
Releasing the mechanism externally
(only with a release cable installed).
Rotate the handle "
A
" through 90°. Hold it in this position and press on
the door to open it. The release mechanism works immediately. Rotating
the handle frees the reduction motor gears.
Locking the mechanism externally
Move the door to the desired position and rotate the handle "
A
"
towards the closed position. The reduction motor gears may not lock
immediately but it can be locked manually by pressing on the door or
by reactivating the motor.
Releasing the mechanism internally
Operate the lever "
L
" (fig.6a) until it reaches the release position (fig.6c)
where it will remain thanks to an anti return mechanism.
Locking the mechanism internally
Lightly press, in the opposite direction, on the lever "
L
" (fig.6a) to over-
come the anti-return mechanism. The presence of the spring will make
the mechanism automatically return to the blocked position (fig. 6a). The
reduction motor gears may not lock immediately but they can be locked
manually by pressing on the door or by reactivating the motor.
Electronic programmer with an incorporated radio receiver card, which
allows the memorisation of
300 user codes
.
The ‘rolling code’ type decoder uses
433 MHz (S449) and 868 MHz
(S486)
series transmitters.
Programming is carried out using single button and allows you to set
the work and pause times.
Electrical connection
Before connecting the appliance make sure that the voltage and fre-
quency rated on the data plate conform to those of the mains supply.
• The appliance works off a single phase
230V 50Hz
power supply.
• The appliance must be earthed. To this end there is a binding post
on the electronics card marked with the symbol to which the earth
wire must be attached.
• Do not use cables with aluminium conductors; do not solder the ends
of cables which are to be inserted into the binding posts.
An all pole trip switch with a least
3mm
between the contacts
must be installed between the unit and the mains supply.
• During the installation make sure that cables do pass near the night
light (
230V 40W
).
• Use insulted channelling to run the cables along the garage door.
• User the lowest hole on the motor support bracket "
A
" (fig.9) to pass
the cable into the appliance.
• To connect the appliance follow the wiring diagram on page 8.
• The microswitch located on the an eventual second motor can be
used as a closing direction travel limit.
Setting the torque limiter (fig.10)
The installer must set the torque selector switch to the appropriate
voltage depending on the weight and dimensions of the door which is
to be automated.
The safety standards in force indicate a maximum thrust at the head
of the gate equal to
150N
. To set the torque limier start from the lowest
value and increase the setting until the garage door moves uniformly.
The appliance will give a maximum power thrust for the first 2,5 seconds
each time it receives a movement command even if the setting switch
is set to minimum.
Legend
B1
Signal buzzer "via radio" mode
F1
3,15A
delayed fuse (
230V
power supply)
F2
1A
rapid action fuse (circuit
24V
)
F3
3,15A
rapid action fuse (electric lock)
J1
Channel selection jumpers
J2
Enable transmitter memorisation via radio
(without opening the container)
L1
LED time programming
L2
LED transmitter code memorisation
L3
LED blocking button activated
L4
LED inverting photocells activated
L5
LED power on
M1
Code memory module
P1
Time programming button "
TPR
"
P2
Code memorising button "
MEMO
"
P3
Code cancelling button "
dEL
"
R1
Radio frequency module
S1
Torque limiter "
Max - A - B - C - Min
"
S2
Function mode selection.
MA
X
A
B
C
MIN
Collegamenti scheda base
PRG805
28-02-2002
dC0357
Description :
Product Code :
Date :
Drawing number :
P.J.Heath
CARdIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
PRG805 con S449 remote
ON
22
23
P3
S2
1
2
5
6
3
4
8
9
7
1
2
TB
TD
FTC_I
FCC
FCA
NC
NC
NC
NC
NA
OUT 24V~10W
LP
Com.
Com.
Com.
ELS12V~
LC 230V~
M
Chiusura
C.
Apertura
Comune
F
N
230V~
P2
J1
1
2
2
1
1
2
1
2
Pos.
A
Pos.
B
Pos.
C
Pos.
D
CHD
CHC
CHB
CHA
L1
L2
L3
L4
L5
M
A
X
A
B C
M
IN
F3.15A
F1A
F3.15A
S1
F1
F2
F3
CS1148A DC0357
12
13
15
16
17
18
19
20
21
14
10
11
S2
J1
P1
CHD
CHC
CHB
CHA
CH1
CHD
CHC
CHB
CHA
CH2
J2
24C16
M1
M1
B1
R1
J2
Position "
Max
" equals:
230V~
Position "
A
"
equals:
195V~
Position "
B
"
equals:
170V~
Position "
C
"
equals:
145V~
Position "
MIN
" equals:
120V~
MANUAL RELEASE MECHANISM (FIG.6)
10
ELECTRONIC PROGRAMMER
ELECTRONICS CARd