14.7 Electrical Components
14.7.1 Electrical Parts Requiring Work After
Replacement
0007-0672
iR105i/iR105+ / iR9070 / iR8070
T-14-6
14.7.2 Electrical Components Requiring Work After
Replacement
0008-8442
iR7200
T-14-7
14.7.3 Electrical Parts Requiring Work After
Replacement
0008-9084
iR85+
T-14-8
14.7.4 When Replacing the HDD
0008-2616
iR105i/iR105+ / iR9070 / iR85+ / iR8070
1) Format the HDD.
Start up the machine in safe mode (i.e., while holding down the 2 and 8
keys, turn on the main power).
Using the HD format function of the SST, format all partitions ($); for
details, see the descriptions given for upgrading.
2) Download the system software.
Using the SST, download the following: System, LANGUAGE, RUI,
PS-FRONT, OCR dictionary, SSL coding key, SSL CA certificate,
MEAP content.
14.7.5 When Replacing the Main Controller PCB
0008-2701
iR105i/iR105+ / iR9070 / iR8070
If you are replacing the main controller PCB, be sure to transfer the
following components from the old to new PCB:
[1] BootROM
[2] HDD
[3] image memory (SDRAM)
[4] counter memory PCB
F-14-67
If the user uses NetSpot Accountant (NSA) in Combination with a
Card Reader
The SDRAM of the main controller retains card ID used by NSA. If you
have replaced the main controller, you will have to download the card
data from NSA once again to permit NSA to perform statistical
operations.
If you have formatted the HDD and downloaded the system software,
you will have to go through a specific set of steps:
1) Format the HDD.
2) Download the system software.
3) Make the following selections:
COPIER>FUNCTION>INSTALL>CARD.
4) Enter a card No.
Enter the first of the numbers that will be used for group control,
and press the OK key (e.g., if you are planning to use cards from
No. 1 thorough No. 100, enter '1').
5) turn off and then on the main power.
6) Check the count control mechanism in user mode.
system control setup>group ID control>count control
check to see as many as 'ID00000001 through ID00001000' have been
prepared.
7) Set the IP address in user mode.
system control setup>network setup>TCP/IP setup>IP address
Set 'IP address', 'gateway address', and 'sub net mask'.
8) Enter a number of your choice in user mode.
system administrator info setup>system control group ID>system
control ID No.
9) Hold down the control panel power switch for 3 sec or more.
10) Go through the instructions on the control panel for shut-down
sequence so that the main power switch may be turned off.
11) Turn off the main power switch. Wait for 3 sec or more, and turn it
back on.
Parts name
Scanning lamp
CCD unit
Reader controller PCB
Main controller PCB
HDD unit
DC controller PCB
HV-DC PCB
Laser unit
Potential sensor/potential control PCB
Part name
Standard white plate
Scanning lamp
CCD unit
Reader controller PCB
Main controller PCB
HDD unit
DC controller PCB
High-voltage DC PCB
Laser unit
Potential sensor/potential control PCB
Parts name
Main controller PCB
HDD unit
DC controller PCB
HV-DC PCB
Laser unit
Potential sensor/potential control PCB
[1]
[2]
[3]
[4]
Содержание ImageRunner iR8500 Series
Страница 1: ...Apr 5 2005 Service Manual iR8500 Series ...
Страница 2: ......
Страница 6: ......
Страница 32: ...Contents ...
Страница 33: ...Chapter 1 Introduction ...
Страница 34: ......
Страница 98: ......
Страница 99: ...Chapter 2 Installation ...
Страница 100: ......
Страница 180: ...Chapter 2 2 78 F 2 272 2 1 1 3 ...
Страница 181: ...Chapter 3 Basic Operation ...
Страница 182: ......
Страница 184: ......
Страница 207: ...Chapter 4 Main Controller ...
Страница 208: ......
Страница 245: ...Chapter 4 4 35 F 4 72 1 2 ...
Страница 246: ......
Страница 247: ...Chapter 5 Original Exposure System ...
Страница 248: ......
Страница 252: ......
Страница 258: ...Chapter 5 5 6 T 5 6 1 Fuse PCB 4 Inverter PCB 2 Reader controller PCB 5 CCD AP PCB 3 Differential PCB ...
Страница 306: ......
Страница 307: ...Chapter 6 Image Processing System ...
Страница 308: ......
Страница 310: ......
Страница 319: ...Chapter 7 Laser Exposure ...
Страница 320: ......
Страница 322: ......
Страница 335: ...Chapter 8 Image Formation ...
Страница 336: ......
Страница 340: ......
Страница 399: ...Chapter 9 Pickup Feeding System ...
Страница 400: ......
Страница 404: ......
Страница 482: ......
Страница 483: ...Chapter 10 Fixing System ...
Страница 484: ......
Страница 524: ......
Страница 525: ...Chapter 11 External and Controls ...
Страница 526: ......
Страница 530: ......
Страница 583: ...Chapter 12 MEAP ...
Страница 584: ......
Страница 586: ......
Страница 589: ...Chapter 13 Maintenance and Inspection ...
Страница 590: ......
Страница 592: ......
Страница 610: ...Chapter 13 13 18 F 13 17 1 2 3 ...
Страница 648: ......
Страница 649: ...Chapter 14 Standards and Adjustments ...
Страница 650: ......
Страница 654: ......
Страница 723: ...Chapter 15 Correcting Faulty Images ...
Страница 724: ......
Страница 728: ......
Страница 792: ......
Страница 793: ...Chapter 16 Self Diagnosis ...
Страница 794: ......
Страница 796: ......
Страница 841: ...Chapter 17 Service Mode ...
Страница 842: ......
Страница 1076: ......
Страница 1077: ...Chapter 18 Upgrading ...
Страница 1078: ......
Страница 1080: ......
Страница 1108: ...Chapter 18 18 28 F 18 45 3 Click Start F 18 46 4 Click Save F 18 47 5 Click OK ...
Страница 1111: ...Chapter 19 Service Tools ...
Страница 1112: ......
Страница 1114: ......
Страница 1120: ......
Страница 1121: ...Apr 5 2005 ...
Страница 1122: ......