2
2
2-50
2-50
Technical Explanation > Image Formation System > Controls > Toner Supply Area
Technical Explanation > Image Formation System > Controls > Toner Supply Area
●
Opening/Closing of Toner Container Shutter
Purpose: To automatically open and close the Toner Container shutter
Toner Head Assembly
Toner Container
Claw
Lever
Shutter
F-2-63
●
Bottle State Detection
Purpose: To detect the state of the Toner Container
The Bottle New/Old Detection Sensor (Y/M/C/Bk) (UN39/UN40/UN41/UN42) detects the state
from the IC tag of the Toner Container.
UN39,40,41,42
[1]
Screen display
Message
Status
Wrong cartridge color may be inserted.
A toner cartridge of the wrong color is inserted
Wrong item no. cart. may be inserted.
A toner cartridge with the wrong item number is inserted.
Toner cart. may be malfunctioning.
The inserted toner cartridge may have been damaged.
----
The correct toner cartridge is inserted.
F-2-64
F-2-65
T-2-35
Содержание imageRUNNER ADVANCE C3325 Series
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 324: ...5 5 Adjustment Adjustment Pickup Feed System Document Exposure System Actions after Replacement ...
Страница 427: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 552: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...
Страница 935: ... Service Tools General Circuit Diagram Backup Data Detail of HDD partition Soft counter specifications Removal Appendix ...
Страница 937: ...III III Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...