2
2
2-128
2-128
Technical Explanation > MEAP > Troubleshooting > Points to Note When Enabling the [Quick Startup Settings for Main Power] Setting
Technical Explanation > MEAP > Troubleshooting > Points to Note When Enabling the [Quick Startup Settings for Main Power] Setting
■
How to Deal with a Message "Certificate Error" That Appears at
the Time of Access
When accessing from the browser to SMS, a message "Certificate Error" appears in some
cases. In this case, perform the procedure indicated in [Top] > [Security] > [Key Pair and
Server Certificate Settings for Encrypted SSL Communication] in the e-Manual to resolve the
error.
Note:
The IP address of the device (or the FQDN in environments where name resolution
is enabled) can be entered in the [Common Name] column to prevent the "Certificate
Error" that is displayed when accessing with Internet Explorer 7 or later.
■
If the MEAP application cannot be started
If the conditions to start the MEAP application are not satisfied, the MEAP application cannot
be started.
If the MEAP application cannot be started, check the following items.
●
Is a valid license installed?
If the license has expired, you cannot start the application. If the license has already expired,
obtain a new license and then update the license. ( See "Procedure Adding a License File" in
this manual.)
●
Are the necessary resources available?
If the resources such as memory capacity or number of threads are not sufficient, the
application also cannot be started.
Delete any unnecessary data to secure sufficient resources.
If the application still cannot be started after checking the foregoing conditions, contact the
support department of the sales company.
■
Points to Note When Enabling the [Quick Startup Settings for
Main Power] Setting
If some of the MEAP applications are running on the device, the following problems will occur.
●
The [Quick Startup Settings for Main Power] setting cannot be
enabled.
If a MEAP application that restricts the device from shifting to deep sleep mode is running,
even when the setting of [Quick Startup Settings for Main Power] is enabled (On), the device
starts normally instead of quick startup.
In that case, it does not affect the behavior of the MEAP application.
●
Changes made in the settings of a MEAP application are not
reflected.
If the startup setting [Quick Startup Settings for Main Power] is enabled (On), even when the
Main Power Supply Switch of the machine is turned OFF, a shutdown process is not executed
internally.
Therefore, in the case of a MEAP application where changes in settings are enabled when
the device is restarted, changes in settings are not reflected just by changing the settings.
Follow either of the restart procedures shown below to enable the changes made in the
settings.
• Execute restart from remote UI.
• Turn OFF the Main Switch, and then turn it ON within 20 seconds.
Содержание imageRUNNER ADVANCE C3325 Series
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 324: ...5 5 Adjustment Adjustment Pickup Feed System Document Exposure System Actions after Replacement ...
Страница 427: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 552: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...
Страница 935: ... Service Tools General Circuit Diagram Backup Data Detail of HDD partition Soft counter specifications Removal Appendix ...
Страница 937: ...III III Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...