8
8
8-39
8-39
Service Mode > COPIER > DISPLAY > DENS
Service Mode > COPIER > DISPLAY > DENS
COPIER>DISPLAY>DENS
P-B-S-C
Dspl ITB front side base intnsty (Swave)
Lv.2 Details
To display the ITB background light intensity (S-wave) detected by
the Registration Patch Sensor Unit (Front).
At low density or fogging deterioration, use this item to check
whether there is a problem in the Registration Patch Sensor Unit
(Front).
Use case
At low density or fogging deterioration
Display/adj/set range
0 to 1023
Appropriate target value 10 - 300
P-D-S-Y
Dspl rear side (Y/M) drk crrnt (Swave)
Lv.2 Details
To display the Y/M-color dark current (S-wave) detected by the
Registration Patch Sensor Unit (Rear).
At low density or fogging deterioration, use this item to check
whether there is a problem in the Registration Patch Sensor Unit
(Rear).
Use case
At low density or fogging deterioration
Display/adj/set range
0 to 1023
Appropriate target value 10 - 100
P-D-S-C
Dspl front side (C/Bk) drk crrnt (Swave)
Lv.2 Details
To display the C/Bk-color dark current (S-wave) detected by the
Registration Patch Sensor Unit (Front).
At low density or fogging deterioration, use this item to check
whether there is a problem in the Registration Patch Sensor Unit
(Front).
Use case
At low density or fogging deterioration
Display/adj/set range
0 to 1023
Appropriate target value 10 - 100
DENS-K-H
Dspl Bk-clr TD ratio diff log: ATR ctrl
Lv.2 Details
To display the latest 8 logs in which deviations (%) of Bk-color toner
density (TD ratio) detected by the ATR Sensor at ATR control from
the target value are shown.
Sharp change in values may indicate ATR Sensor disconnection/
failure, whereas gradual change in values may indicate failure in
toner supply system.
Use case
When checking the toner density in the Developing Unit at low
density or fogging deterioration
Display/adj/set range
-700 to 700
Unit
0.01 %
Appropriate target value -300 - 300
SPL-LG-K
Display of Bk-color toner supply log
Lv.2 Details
To display the latest 8 Bk-color toner supply log data.
Each data represents the number of toner blocks supplied per paper.
Use case
When checking toner supply status at E020 occurrence, low density
or fogging deterioration
Display/adj/set range
0 to 100
Appropriate target value 0 - 10
COPIER>DISPLAY>DENS
Y-LED-DA
Dspl rear side Patch Sensor intensity
Lv.1 Details
To display the LED light intensity of the Registration Patch Sensor
Unit (Rear).
If the value is out of the appropriate range, clean the window of the
Registration Patch Sensor Unit. If the problem is not solved, it is
considered as a failure of the sensor.
Use case
When an error related to the Patch Sensor occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 60 - 240
C-LED-DA
Dspl front side Patch Sensor intensity
Lv.1 Details
To display the LED light intensity of the Registration Patch Sensor
Unit (Front).
If the value is out of the appropriate range, clean the window of the
Registration Patch Sensor Unit. If the problem is not solved, it is
considered as a failure of the sensor.
Use case
When an error related to the Patch Sensor occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 60 - 240
T-8-13
Содержание imageRUNNER ADVANCE C3325 Series
Страница 16: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Страница 324: ...5 5 Adjustment Adjustment Pickup Feed System Document Exposure System Actions after Replacement ...
Страница 427: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Страница 552: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD ...
Страница 935: ... Service Tools General Circuit Diagram Backup Data Detail of HDD partition Soft counter specifications Removal Appendix ...
Страница 937: ...III III Appendix Service Tools Special Tools Appendix Service Tools Special Tools Solvents and Oils None ...