PRODUCTS AFFECTED / SERIAL NUMBERS AFFECTED:
See Table Below
SUBJECT:
Measure to Prevent E020-0360/ E020-0391/ E020-03b1 (black toner sensor electrostatic buildup)
Additional information regarding the placement of the Claw under the feed assembly and the serial
number cut-off has been added.
PRODUCTS AFFECTED/SERIAL NUMBERS AFFECTED:
Products Affected:
Serial Numbers Affected:
imageRUNNER ADVANCE C2020
FAH00001 ~ FAH10546
imageRUNNER ADVANCE C2030
EZS00001 ~ EZS10828
imageRUNNER ADVANCE C2020 G
GDV00001 ~ GDV10008
imageRUNNER ADVANCE C2030 G
GEB00001 ~ GEB10009
GENERAL:
Measure to prevent E020-0360/ E020-0391/ E020-03b1 error codes due to electrostatic buildup on the black
toner sensor during shipment.
DETAILS:
<Symptom>
Error codes E020-0360/ E020-0391/ E020-03b1 may occur due to electrostatic buildup on the black toner
sensor.
E020-0360: Low density of the target during patch detection.
E020-0391: The average value of the detected inductance sampling value is equal to or higher than the
specified value.
E020-03b1: Error in detecting the delta T/D ratio (T/D ratio detected by the ATR Sensor is equal to or lower
than the specified value).
Added