pg. 13
- If the output has not improved, refer to FAQ titled "Drum ghost due to advanced life of Drum Unit with high
duty/high CV."
Title
Fogging occurs on the whole image
Symptom
Yellow fogging occurs on the whole image. [A] is an incorrect image. [B] is a correct image.
Cause
The connector J832 pin of the Connector PCB in the Laser Scanner Unit is deformed.
Service work
Replace the Laser Scanner Unit.
FM3-8074 LASER SCANNER UNIT
Title
Foggy image in magenta/poor density on solid image.
Symptom
Overall fogging in magenta/poor density on solid image occurred.
Below is a sample of PG test print. [A] shows the symptom. [B] is a normal image.