pg. 116
3) After the screen of step 2) is displayed, the diagnosis result appears in approximately three minutes. The
screen locked up showing step 2) in this case. If the symptom occurs, replace the DDR2-SDRAM. If the
diagnosis result shows "NG", use the Controller System Error Diagnosis Table in Service Manual to conduct
recovery work.
If the result shows "OK", check other factors.
[Reference] Figure [A] below shows the result is normal whereas Figure [B] shows the result is abnormal.
[Replacement Part]
FK2-8341 DIMM, SMD-E51288HG-6E, SDRAM DIMM
Title
Machine not recovering from Sleep Mode upon installation due to foreign substances adhering to DIMM's
contact
Symptom
Machine did not recover from Sleep Mode upon installation.
Cause
Foreign substances adhered to the contact of the DDR2-SDRAM (DIMM), which is installed on the Main
Controller PCB 1.