Section 11. Glossary
583
Term: expression
A series of words, operators, or numbers that produce a value or result.
Field
Final-storage data tables are made up of records and fields. Each row in a
table represents a record and each column represents a field. The number of
fields in a record is determined by the number and configuration of output
processing instructions that are included as part of the
DataTable()
declaration.
Term: FFT
F
ast
F
ourier
T
ransform. A technique for analyzing frequency-spectrum
data.
Term: File Control
File Control
is a feature of
LoggerNet
,
PC400
and
RTDAQ
datalogger
support software
(p. 97).
It provides a view of the CR6 file system
and a menu of file management commands:
Delete
facilitates deletion of a specified file
Send
facilitates transfer of a file (typically a CRBasic program file) from
PC memory to CR6 memory.
Retrieve
facilitates collection of files viewed in
File Control
.
If
collecting a data file from a memory card with
Retrieve
, first stop
the CR6 program or data corruption may result.
Format
formats the selected CR6 memory device. All files, including
data, on the device will be erased.
Term: File Retrieval tab
A feature of
LoggerNet Setup Screen
. In the
Setup Screen
network map
(Entire Network), click on a CR6 datalogger node. The
File Retieval
tab
should be one of several tabs presented at the right of the screen.
Term: fill and stop memory
A memory configuration for data tables forcing a data table to stop accepting
data when full.
Term: final-storage memory
The portion of CR6 SRAM memory allocated for storing data tables with
output arrays. Once data are written to final-data memory, they cannot be
changed but only overwritten when they become the oldest data. Final-data
Содержание CR6 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 36: ......
Страница 38: ......
Страница 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Страница 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Страница 136: ......
Страница 251: ...Section 7 Installation 251 FIGURE 46 Running Average Frequency Response FIGURE 47 Running Average Signal Attenuation ...
Страница 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Страница 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Страница 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Страница 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Страница 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Страница 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Страница 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Страница 542: ...Section 8 Operation 542 8 11 5 PCCard Memory Card Management FIGURE 128 CR1000KD PCCard Memory Card Management ...
Страница 546: ......
Страница 549: ...Section 9 Maintenance Details 549 FIGURE 133 Separate Back Shell from Module FIGURE 134 Disconnect Battery Connector ...
Страница 552: ......
Страница 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Страница 612: ......
Страница 648: ......
Страница 650: ......
Страница 688: ......
Страница 689: ......