Section 8. Operation
407
Four-Wire Full-Bridge Measurement
(p. 409)
lists CRBasic code that measures and
processes four-wire full-bridge circuits.
Offset voltages compensation applies to bridge measurements. In addition to
RevDiff
and
MeasOff
parameters discussed in
Offset Voltage Compensation
(p.
CRBasic bridge measurement instructions include the
RevEx
parameter that
provides the option to program a second set of measurements with the excitation
polarity reversed. Much of the offset error inherent in bridge measurements is
canceled out by setting
RevDiff
,
MeasOff
, and
RevEx
to
True
.
Measurement speed can be slowed when using
RevDiff
,
MeasOff
, and
RevEx
.
When more than one measurement per sensor are necessary, such as occur with
the
BrHalf3W()
,
BrHalf4W()
, and
BrFull6W
instructions, input and excitation
reversal are applied separately to each measurement. For example, in the
four-wire half-bridge (
BrHalf4W()
), when excitation is reversed, the differential
measurement of the voltage drop across the sensor is made with excitation at both
polarities and then excitation is again applied and reversed for the measurement of
the voltage drop across the fixed resistor. Further, the results of measurement
instructions (X) must be processed further to obtain the resistance value. This
processing requires additional program execution time.
Resistive-Bridge Circuits with Voltage Excitation
Resistive-Bridge Type and
Circuit Diagram
CRBasic Instruction and
Fundamental Relationship
Relational Formulas
Half-Bridge
1
CRBasic Instruction:
BrHalf()
Fundamental Relationship
2
:
Three-Wire Half-Bridge
1,3
CRBasic Instruction:
BrHalf3W()
Fundamental Relationship
2
:
Содержание CR6 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 36: ......
Страница 38: ......
Страница 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Страница 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Страница 136: ......
Страница 251: ...Section 7 Installation 251 FIGURE 46 Running Average Frequency Response FIGURE 47 Running Average Signal Attenuation ...
Страница 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Страница 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Страница 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Страница 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Страница 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Страница 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Страница 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Страница 542: ...Section 8 Operation 542 8 11 5 PCCard Memory Card Management FIGURE 128 CR1000KD PCCard Memory Card Management ...
Страница 546: ......
Страница 549: ...Section 9 Maintenance Details 549 FIGURE 133 Separate Back Shell from Module FIGURE 134 Disconnect Battery Connector ...
Страница 552: ......
Страница 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Страница 612: ......
Страница 648: ......
Страница 650: ......
Страница 688: ......
Страница 689: ......