10. Troubleshooting
If a system is not operating properly, please contact a Campbell Scientific support
engineer for assistance. When using sensors, peripheral devices, or comms
hardware, look to the manuals for those products for additional help.
Note
If a Campbell Scientific product needs to be returned for repair or
recalibration, a
Return Materials Authorization
(p. 5)
number is first required.
Please contact a Campbell Scientific support engineer.
10.1 Troubleshooting — Essential Tools
•
Multimeter (combination volt meter and resistance meter). Inexpensive
($20.00) meters are useful. The more expensive meters have additional
modes of operation that are useful in some situations.
•
Cell or satellite phone with contact information for Campbell Scientific
support engineers. Establish a current contact at Campbell Scientific
before going to the field. A support engineer may be able to provide
you with information that will better prepare you for the field visit.
•
Product documentation in a reliable format and easily readable at the
installation site. Sun glare, dust, and moisture often make electronic
media difficult to use and unreliable.
10.2 Troubleshooting — Basic Procedure
1. Check the voltage of the primary power source at the
CHG
and
BAT
terminals on the face of the CR6.
2. Check wires and cables for the following:
o
Loose connection points
o
Faulty connectors
o
Cut wires
o
Damaged insulation, which allows water to migrate into the cable.
Water, whether or not it comes in contact with wire, can cause
system failure. Water may increase the dielectric constant of the
cable sufficiently to imped sensor signals, or it may migrate into the
sensor, which will damage sensor electronics.
3. Check the CRBasic program. If the program was written solely with
Short
Cut
, the program is probably not the source of the problem. If the program was
written or edited with
CRBasic Editor
, logic and syntax errors could easily
have crept into the code. To troubleshoot, create a stripped down version of
the program, or break it up into multiple smaller units to test individually. For
Содержание CR6 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 36: ......
Страница 38: ......
Страница 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Страница 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Страница 136: ......
Страница 251: ...Section 7 Installation 251 FIGURE 46 Running Average Frequency Response FIGURE 47 Running Average Signal Attenuation ...
Страница 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Страница 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Страница 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Страница 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Страница 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Страница 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Страница 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Страница 542: ...Section 8 Operation 542 8 11 5 PCCard Memory Card Management FIGURE 128 CR1000KD PCCard Memory Card Management ...
Страница 546: ......
Страница 549: ...Section 9 Maintenance Details 549 FIGURE 133 Separate Back Shell from Module FIGURE 134 Disconnect Battery Connector ...
Страница 552: ......
Страница 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Страница 612: ......
Страница 648: ......
Страница 650: ......
Страница 688: ......
Страница 689: ......