6
PROGRAMMING
The 7600 can be placed into the "Program" mode by use of the new
9075 Smart Programmer
, or the
original 8950 programmer, or for Keypad programming, by utilizing the 9050 LCD Keypad or the 8601 LED
Keypad. These methods are described below.
Using a Programmer
Plug the optional 8950 Programmer into the 4-pin male outlet marked “PROGRAMMER” on the Ranger
7600 PC Board and the control will enter the program mode. The 8950 will program locations “000"
through “255" of the 7600 control (See using the LED Keypad below.) When using a 9075 Smart
Programmer, please refer to the 9075 Manual.
Using The LCD Keypad
The most straightforward method of Keypad programming is to utilize the 9050 LCD Keypad in the
programming mode. To access the programming mode enter [
C
]-[
0
]-[
0
], followed by the four digit "Go To
Program" access code which is factory default [
9
]-[
0
]-[
5
]-[
0
] (this code can be reprogrammed), and follow
the Keypad prompts. (See using the LED Keypad below.)
Using The LED Keypad
The 7600 can also be programmed by the standard binary method of Keypad programming described
below. When the 8601 LED Keypad is used for programming, enter the factory default four digit "Go To
Program" access code of [
9
]-[
7
]-[
1
]-[
3
]. NOTE: The 7600 must be disarmed to gain access to programming
with this code. After entry of this code, the 7600 will be in the "Program" mode, and the yellow LED's will
display the data in location 000. The data is displayed using a Binary system. With this system the yellow
zone 1 LED equals "1" when illuminated. The zone 2 LED equals "2" when illuminated. The zone 3 LED
equals "4" when illuminated. The zone 4 LED equals "8" when illuminated. Thus if the data in location 000
is "9", the LED for zone 1 (=1) and zone 4 (=8) would be illuminated. By adding the two values together,
(1+8=9) you would determine that the data in location 000 is "9". If the data in location 000 is "6", the LEDs
for zone 2 (=2) and zone 3 (=4) would be added (2+4=6) indicating the data in that location to be "6". If no
LED's are illuminated, the location contains a "0". To advance from location 000 through 255, press the
[#] key. To go to a specific location, press the location number followed by the [
#
] key. The yellow LED's
will then display the data in that location. Data is changed by entering a number 0 to 15 followed by [
r
]
(
r
= data enter). Review the examples in figure 1 on the following page.
Important Function Codes
[9]-[1]-[0]-[#]
When in the program mode, this function code can be used to write original factory
default codes into the 7600.
[9]-[3]-[0]-[#]
This function code is used to exit the programming mode after it was accessed via the
Keypad.