LOCATION 176: SPLIT REPORTING - PROGRAMMING TAMPER, DOWNLOAD COMPLETE, AND AUTOTEST
TO REPORT TO THE SECONDARY PHONE NUMBER.
The 7600 is capable sending certain reports to the secondary telephone number. This feature known as split
reporting can be used to send alarm reports to one number and supervisory reports to another number. When using
split reporting with the 7600, the primary telephone number always takes priority over the secondary telephone
number. The 7600 always sends zone and alarm reports to the primary telephone number. There are 6 reports that
can be programmed to report to the second telephone number. Location 176 is used to force up to three of these
individual reports to the second telephone number. To program tamper, download complete, or autotest to report
to the secondary telephone number, use the following chart and program the appropriate number in location 176.
For Dual Reporting see locations 204-206.
REPORTS TO SEND TO SECONDARY NUMBER
DATA TO PROGRAM IN LOCATION 176
AUTOTEST
"2"
DOWNLOAD COMPLETE
"4"
DOWNLOAD COMPLETE ; AUTOTEST
"6"
TAMPER
"8"
TAMPER ; AUTOTEST
A = "10"
TAMPER ; DOWNLOAD COMPLETE
C = "12"
TAMPER ; DOWNLOAD COMPLETE ; AUTOTEST
E = "14"
LOCATION 177: SPLIT REPORTING - PROGRAMMING AC POWER FAIL, LOW BATTERY, AND OPEN/CLOSE
TO REPORT TO THE SECONDARY PHONE NUMBER
The 7600 is capable sending certain reports to the secondary telephone number. This feature known as split
reporting can be used to send alarm reports to one number, and supervisory reports to another number. When using
split reporting with the 7600, the primary telephone number always takes priority over the secondary number. The
7600 always sends zone and alarm reports to the primary number. There are 6 reports that can be programmed to
report to the second telephone number. Location 177 is used to force up to three of these individual reports to the
second number. To program AC power fail, low battery, or open/close to report to the secondary number, use the
following chart and program the appropriate data in this location.
REPORTS TO SEND TO SECONDARY NUMBER
DATA FOR LOCATION 177
OPEN/CLOSE
"2"
LOW BATTERY
"4"
LOW BATTERY; OPEN/CLOSE
"6"
AC FAIL
"8"
AC FAIL; OPEN/CLOSE
A = "10"
AC FAIL; LOW BATTERY
C = "12"
AC FAIL; LOW BATTERY; OPEN/CLOSE
E = "14"
LOCATION 178: PROGRAMMING THE SECONDARY ENTRY DELAY
Location 178 contains the number of 10 second increments in the secondary entry delay. This delay can be
programmed from 10 to 150 seconds (“1" = 10 sec. through “15" = 150 sec.) NOTE: ACCORDING TO SECTION
26 OF U.L. 1023, THE SECONDARY ENTRY TIME SHALL NOT EXCEED 45 SECONDS.
LOCATION 179: PROGRAMMING THE SECONDARY EXIT DELAY (ZONE TYPE 9)
Location 179 contains the number of 10 second increments after arming, before trips will be recognized on a zone
type 9. The exit delay can be programmed in 10 second increments from 10 to 150 seconds ("1" = 10 seconds
through "15" = 150 seconds). (Note: A "0" entry is treated as zero (0) seconds). If the exit delay time in this location
is less than that of location 076, this secondary delay will follow the amount of time in location 076.