LOCATION 192-195: RESERVED

LOCATION 196: ANSWERING MACHINE DEFEAT

     
Location 196 contains the answering machine defeat. To defeat an answering machine, two telephone calls must
be made to the premises. On the first call, let the phone ring the same number of times (or less) as the number
programmed in this location (maximum 3) and disconnect. The control panel will detect these rings and start a 45
second timer, during which, the control panel will answer the next call on the first ring. This location will override
location 280 if it contains something other than a “0" (factory default). 

LOCATION 197: FORCE ARMING

     
Programming a "1" in location 197 will allow the Ranger 7600 to be armed without all zones secure (no "Ready" LED
illuminated). At the end of the exit delay, unsecured zones will automatically bypass, while zones that secure will
become armed. Factory default is "0", Force Arming disabled.

LOCATIONS 198-201: AUTOMATIC ARMING TIME

Locations 198-201 contain the time for automatic arming if enabled in location 202. Enter the time in 24 hour time.
    

LOCATION 202: AUTOMATIC ARMING

     
Programming a "1" in location 202 will enable Automatic arming. The arming time is programmed in location
198-201. If automatic arming is enabled, the keypad sounder will activate for 50 seconds before automatically
arming. If the sounder is silenced by entering a valid arm/disarm code during the 50 second time frame, the panel
will not arm. If the sounder is still on at the end of 50 seconds, the control will arm. Any zones not secured will be
bypassed when automatic arming is used.

LOCATION 203: DYNAMIC BATTERY TEST

     
The number programmed in location 203 determines the number of minutes (1 to 15) the 7600 will perform dynamic
battery testing during each 24 hour period. The red "Power" LED will flash if the battery fails the dynamic test.
Factory default is "0" (disabled).
     

Содержание RANGER 7600

Страница 1: ...RAM THE RANGER 7600 6 KEYPAD PROGRAMMING EXAMPLES 7 OPTIONAL 8950 PROGRAMMER EXAMPLE 7 PROGRAMMING INSTRUCTIONS 8 28 PROGRAMMING WORKSHEETS 29 32 APPENDIX 1 33 APPENDIX 2 34 LOCAL TELEPHONE COMPANY IN...

Страница 2: ...s Read the USER S MANUAL before you begin the installation for the best overall description of how the Ranger 7600 functions After installation of the security system complete the information on page...

Страница 3: ...duration at 6 00 AM Page 22 Location 203 ENTRY GUARD This unique low level arming mode has been developed to reduce the most common source of false alarms When armed in this mode the opening of any z...

Страница 4: ...4 TERMINAL DRAWING SPECIAL NOTES...

Страница 5: ...OOP 8 Connect one side of zone 6 loop The other side of loop to common terminal 6 Open only causes alarm DO NOT USE 3 3K EOL RESISTOR ON THIS LOOP 9 10 Auxiliary power regulated 12VDC 500 mA maximum 1...

Страница 6: ...9 7 1 3 NOTE The 7600 must be disarmed to gain access to programming with this code After entry of this code the 7600 will be in the Program mode and the yellow LED s will display the data in locatio...

Страница 7: ...7...

Страница 8: ...l 4 2 program a 1 in location 052 Contact ID requires a 13 in this location If you need another format choose from those listed in the format table located on the following page and program the data i...

Страница 9: ...FAST 1800HZ TRANSMIT 2300HZ 20PPS 5 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 2300HZ HANDSHAKE DOUBLE ROUND PARITY 20 PPS EXTENDED HEX CAPABILITY 6 EXTENDED RADIONICS SLOW 1800HZ TRANSMIT 1400HZ HANDSH...

Страница 10: ...th the Ranger 7600 disarmed the Go To Program access code can be used to enter the program mode To disable the Go To Program access code program a 15 in location 028 The factory default setting is 9 7...

Страница 11: ...ode then pressing r 6 INSTANT Produces an instant alarm when tripped in the armed mode ignored when disarmed 7 24 HOUR SILENT A trip on a 24 hour silent zone will communicate to the central station wh...

Страница 12: ...aneously on the keypad The desired Auxiliary 2 code is programmed in locations 090 091 If both locations are 0 the Auxiliary 2 double keypress is disabled Location 090 contains the standard digit and...

Страница 13: ...in Location 102 If this location contains a 0 closing will not be reported When using a one button Quick Arm code or the Remote Arming input the man number is 1 When using the Auto Arm feature the man...

Страница 14: ...16 contains the standard digit and location 117 contains the extended digit When Contact ID is selected program the extended or the second location with any number to activate LOCATION 118 119 PROGRAM...

Страница 15: ...nicator code that will be sent for cancel The cancel code programmed in this location will be sent if an arm disarm code is entered after a trip on zones 1 through 6 has been reported excluding 24 hou...

Страница 16: ...ion process If this location contains an 8 the communicator will make 8 attempts to the first number and then eight attempts to a second number if a second number is programmed as backup LOCATION 135...

Страница 17: ...the chart below add the values of the desired condition s and program the sum of those values in location 142 When the siren bell is activated by pressing the 1 and 7 keys simultaneously the communic...

Страница 18: ...MOMENTARY OUTPUT 8 TAMPER ALARM LATCHED OUTPUT 9 AUTOTEST MOMENTARY OUTPUT 10 RESERVED NOT USED 11 ALARM MEMORY LATCHED OUTPUT 12 ENTRY LATCHED OUTPUT 13 EXIT LATCHED OUTPUT 14 SMOKE DETECTOR POWER L...

Страница 19: ...n should contain a 6 which is the ones digit of the current year LOCATION 156 PROGRAMMING THE CLOCK CURRENT DAY OF THE MONTH TENS DIGIT Location 156 contains the current day of the month tens digit If...

Страница 20: ...e desired autotest time is 9 36 AM the 24 hour time is 09 36 and this location should contain a 9 LOCATION 164 PROGRAMMING THE AUTOTEST TIME MINUTES TENS DIGIT Location 164 contains the tens digit of...

Страница 21: ...sed to send alarm reports to one number and supervisory reports to another number When using split reporting with the 7600 the primary telephone number always takes priority over the secondary number...

Страница 22: ...rmat options as follows VALUE DESCRIPTION 1 Add for extended reporting 2 Add for hex digits allowed 4 Add for 20PPS 8 Add for 10PPS LOCATION 183 FORMAT OVER RIDE LOCATION The number selected in this l...

Страница 23: ...secure will become armed Factory default is 0 Force Arming disabled LOCATIONS 198 201 AUTOMATIC ARMING TIME Locations 198 201 contain the time for automatic arming if enabled in location 202 Enter the...

Страница 24: ...OTEST E 14 LOCATION 205 DUAL REPORTING PROGRAMMING AC POWER FAIL LOW BATTERY AND OPEN CLOSE TO REPORT TO THE PRIMARY AND SECONDARY PHONE NUMBERS The 7600 is capable of sending certain reports to both...

Страница 25: ...t options as follows VALUE DESCRIPTION 1 Add for Contact ID 2 Add for SIA 4 Add for 4 3 8 Add for DTMF transmission LOCATION 210 PROGRAMMING TO REPORT EXIT ERROR The Ranger 7600 has the ability to rep...

Страница 26: ...rt VALUE DESCRIPTION 1 Cross Zone 2 Entry Guard Zone 4 Group Bypass Zone 8 Trouble Reporting CROSS ZONING This feature requires a trip on 2 or more zones programmed as Cross Zones within the time fram...

Страница 27: ...by entering r 0 followed by a valid arm disarm code at the keypad when the system is not armed This can be used to log the return of latch key kids or the presence of employees The desired user on si...

Страница 28: ...l comes in during that 45 second time frame the control panel will answer on the first ring To disable this feature program a 0 in this location LOCATION 281 LOCAL PROGRAMMING LOCKOUT Location 281 is...

Страница 29: ...0 073 9 SECONDARY ACCOUNT CODE 0 DISABLED 074 9 SECONDARY FORMAT 0 DISABLED CONTROL COMMUNICATOR FEATURES LOCATION PAGE DESCRIPTION DATA DEFAULT 075 10 ENTRY DELAY TIME 10 SECOND INCREMENTS 3 30 SECON...

Страница 30: ...E DIAL TIME 0 DISABLED 129 15 KEYPAD PANIC SILENT OR AUDIBLE 0 AUDIBLE 130 15 LIMITED SIREN AND OR COMMUNICATOR OUTPUTS 0 UNLIMITED 131 16 AUTO BYPASS INSTANT ARMING 0 DISABLED 132 16 ENABLE KEYPAD SI...

Страница 31: ...ONE 1 177 20 SPLIT REPORTING AC FAILURE LOW BAT OPEN CLOSE 0 PHONE 1 178 20 SECONDARY ENTRY DELAY TIME 0 179 21 SECONDARY EXIT DELAY TIME 0 180 21 LOOP RESPONSE TIME 0 500 MS 181 21 AUTOTEST SUPPRESSI...

Страница 32: ...8 245 25 ZONE 2 SPECIAL CHARACTERISTICS 8 246 25 ZONE 3 SPECIAL CHARACTERISTICS 8 247 25 ZONE 4 SPECIAL CHARACTERISTICS 8 248 25 ZONE 5 SPECIAL CHARACTERISTICS 8 249 25 ZONE 6 SPECIAL CHARACTERISTICS...

Страница 33: ...ent SIA Code Description 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 GA Gas Alarm 5 KA Heat Alarm 6 WA Water Alarm 7 QA Emergency Alarm 8 SA Sprinkler Alarm 9 UA Untyped Alarm 10 HA Holdup...

Страница 34: ...Code Contact ID Code Description 1 110 Fire Alarm 2 122 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 Hour Burglary 7 134 Entry Alarm 8 135 Day Night Alarm 9 15...

Страница 35: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Страница 36: ...36 NOTES...

Страница 37: ...INSIDE BACK COVER IS BLANK...

Страница 38: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...

Отзывы: