TERMINAL DESCRIPTION
DESCRIPTION
1
Connect one side of zone 1 loop. The other side of loop to common terminal 3. Open
or short causes alarm.
2
Connect one side of zone 2 loop. The other side of loop to common terminal 3. Open
or short causes alarm.
3
Loop Common For zones 1-3
4
Connect one side of zone 3 loop. The other side of loop to common terminal 3. Open
or short causes alarm.
5
Connect one side of zone 4 loop. The other side of loop to common terminal 6. Open
or short causes alarm.
6
Loop Common for zones 4-6.
7
Connect one side of zone 5 loop. The other side of loop to common terminal 6. Open
only causes alarm. (
DO NOT USE 3.3K EOL RESISTOR ON THIS LOOP.
)
8
Connect one side of zone 6 loop. The other side of loop to common terminal 6. Open
only causes alarm. (
DO NOT USE 3.3K EOL RESISTOR ON THIS LOOP.
)
9(-)&10(+)
Auxiliary power, regulated 12VDC, 500 mA maximum.
11
Programmable output current limited at 20 mA when switched negative.
12,13,14,15
Connect keypad wires as follows; yellow to terminal 12, green to terminal 13, black to
terminal 14, red to terminal 15. Wire run 200 feet maximum with 22 gauge, 500 feet
maximum with 18 gauge. Home run cable to each keypad.
16
Earth Ground, connect to a cold water pipe or 6 to 10 foot driven rod.
17 & 18
AC input; connect a 16.5V 25 VA, approved transformer.
19(+)&20(-)
Siren/Bell voltage output, 12VDC, 1 Amp maximum load.
T1 & R1
House Telephones Connection.
T & R
Incoming Telephone Line Connection.
FUSE DESCRIPTION
FUSE NO.
DESCRIPTION
F1
1 AMP / Keypad & AUX Power
F2
2 AMP / Siren Voltage Output