APPENDIX 1 - REPORTING IN SIA FORMAT
The 7600 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA
consists of an Event Code and a Zone or User ID. The Zone is programmed in the first digit of each report. When
programming the event code (the second digit) for zones 1-6 (locations 105, 107, 109, 111, 113, or 115),
programming a zero will cause the event code to follow the zone type for that zone. The event code for the zone type
can be overridden by programming a digit from the table below. Duress (location 87), AUX 1 (location 89), AUX 2
(location 91), and Keypad Panic (location 93) must be programmed from the table below.
Programmed Event
SIA Code
Description
1
FA
Fire Alarm
2
PA
Panic alarm
3
BA
Burglary Alarm
4
GA
Gas Alarm
5
KA
Heat Alarm
6
WA
Water Alarm
7
QA
Emergency Alarm
8
SA
Sprinkler Alarm
9
UA
Untyped Alarm
10
HA
Holdup Alarm
11
MA
Medical Alarm
12
ZA
Freeze Alarm
13
TA
Tamper Alarm
14
RP
Periodic Test
15
YF
System Fault
The following reports will send fixed event codes regardless of the number programmed in the event code location:
Event
SIA Code
Event Code Location
Keypad Tamper
TA
95
Download Complete
RS
97
Autotest
RP
99
Fail to Communicate
RT
101
Closing
CL
102
Opening
OP
103
Start Test
TS
116
End Test
TE
116
AC Loss
AT
121
Low Battery
YT
123
Trouble
T*
124
Bypass
B*
125
Bypass Restore
U
*
125 - 126
Restore
R
*
126
Cancel
OC
127
Exit Error
EE
210
Recent Closing
CR
211
Auxiliary 3
UA
253
User on site
YY
254
*These will send the event code for the zone bypassed, restored, or in trouble.