FEATURE DEFINITIONS
ALARM HISTORY
- Five seconds after pressing the [0] key, the keypad will annunciate “Freeze Frame” alarm
history. The zone LED’s will indicate which zone(s) caused the last alarm, regardless of the number of times the
Ranger 7600 has been armed or disarmed since that alarm. It annunciates by blinking the zone LED(s) that caused
the alarm, and lighting steady those that were bypassed when that alarm occurred. The annunciation will continue
for 5 seconds. Alarm History is erased when the Ranger 7600 is put into the program mode. A burglary zone that
has been bypassed due to “Swinger Shutdown” will alternate between steady and blinking.
AUTOMATIC ARMING
- The Ranger 7600 can be programmed to Automatically Arm at a predesignated time of day,
if it has not already been armed. (Page 22, Location 202.)
AUTOMATIC BYPASS/INSTANT ARMING
- When enabled, the control panel can automatically bypass interior follower
zones if an exit is not detected during the delay time, and delayed zones can be made instant. (Page 16, Location 131.)
AUXILIARY OUTPUT
- The 7600 has one auxiliary output that can be activated by up to four different events from a
pool of 16 different options. (Page 17, Locations 145-148.
)
CHIME
- If so programmed, this feature can be turned on and off by pressing [
1
]. When the system is in the disarmed
state, the violation of selected zones will create a one second tone through the keypad sounder. Chime is disabled
on all zones from factory. (Page 22 for Locations 186-191.)
CROSS ZONING
- When enabled, the 7600 can be programmed for "Cross Zoning" (Page 25, Locations 244-249)
which is a feature that requires a trip on more than one zone during a specific time frame (Page 25, Location 255) to
verify an alarm condition.
DUAL/SPLIT REPORTING
- The Ranger 7600 can be programmed for dual and/or split reporting.
DYNAMIC BATTERY TEST
- When enabled, the Ranger 7600 can be programmed to perform a dynamic battery test
for a selected duration, at 6:00 AM. (Page 22, Location 203.)
ENTRY-GUARD
- This unique low level arming mode has been developed to reduce the most common source of false
alarms. When armed in this mode, the opening of any zones designated as "Entry Guard zones" will initiate the keypad
sounder and start a delay before creating an alarm. This arming mode will encourage system owners to use their
system more frequently when the premises is occupied. (Page 25, Locations 244-249.)
FIRE ALARM VERIFICATION
- When enabled, the Ranger 7600 has the ability to verify a Fire alarm by requiring more
than one trip on a smoke detector before creating an alarm. (Page 17, Location 143.)
FORCE ARMING
- When enabled, the Ranger 7600 can be armed with zones violated, lacking a green "Ready" light
on the keypad. Under this condition, all zones that are not secure at the end of the exit delay will become bypassed.
All zones that become secured before the end of the exit delay will become active in the system. (Page 22, Location
197.)
GROUP BYPASS
- Zones can be programmed to bypass as a group when the [
r
r
][
9
][
r
r
] keys are pressed while system
is disarmed. (Page 25, Locations 244-249.)
INTERNAL EVENT LOG
- Up to 80 events can be stored in memory along with the date and time of the event. These
events can later be viewed through downloading.
KEYSWITCH ARMING
- Keyswitch arming/disarming can be accomplished by using the remote arming input on the
PC board, and the auxiliary outputs. It is not necessary to waste a hardwire zone to accommodate Keyswitch
arming/disarming.
LCD KEYPAD
- The 7600 will accommodate the Ranger 9050 custom English Language Keypad.
PAGER AND HIGH SPEED FORMATS
- The 7600 has SIA and Contact ID high speed communicator formats. A
pager format is also available for reporting to a pager. (Page 9).
QUICK ARM FEATURE
- The Ranger 7600 has a one button "Quick Arm" code which can be used to arm the system
by pressing one digit at the keypad. (Page 17, Location 139.)
SECONDARY EXIT DELAY
- Used most often for garage doors, this zone type is a second entry/exit delay that has
its own delay times, independent of the standard entry/exit delay zone. (Page 20, Locations 178-179)
Содержание RANGER 7600