Abandoning Changes / Restoring Default Settings
There are two ways to abandon configuration changes:
T
To
o a
ab
ba
an
nd
do
on
n cch
ha
an
ng
ge
ess a
an
nd
d sstto
op
p e
ed
diittiin
ng
g, simply close the Configuration window and choose No when asked if you
would like to save your changes. No changes will be made to the unit configuration.
T
To
o a
ab
ba
an
nd
do
on
n cch
ha
an
ng
ge
ess a
an
nd
d rre
esstta
arrtt e
ed
diittiin
ng
g w
wiitth
h tth
he
e lla
asstt--ssa
avve
ed
d sse
ettttiin
ng
gss, select Revert from the Configuration
window toolbar. This will restore the settings last saved to the I/O unit.
Note: If you are working from an archived .set file and wish to discard changes, re-open the archive file or close the
Configuration window.
To restore the factory-default settings to your I/O unit, select Set to Default Values from the Configuration
window’s File menu.
Note: To restore previously saved data for the current menu tab only, select Re-Download Selected Data from the
File Menu in the Unit Configuration window.
Printing the Unit Configuration
So that operators may easily reference channel assignments and other configuration settings, it may be useful to
print your unit configuration. To do so, click the Print icon in the Configuration window toolbar. You may also
preview the printout by choosing Print Preview from the File menu.
Note: The File menu in the Configuration Window also provides access to the Macro Editor. See chapter 10).
CALIBRATION
The Calibration window is where you calibrate the I/O
unit’s meter readings so that the values reported by
the unit match those of the monitored equipment. If
you are setting up a new site, you need to finish
configuring all the units at your site and go on to set
up modems and connect your site equipment before
calibrating your I/O unit (see Chapter 6). Once this is
done, you are ready to calibrate.
In order to correctly calibrate the metering channels,
you must be direct-connected at the transmitter site or
remotely connected and in communication with
someone in the field who can report actual equipment
values.
To calibrate an I/O unit’s metering channels:
1. Select the desired unit in the Site List.
2. Open the calibration window by expanding S
Se
elle
ecctte
ed
d U
Un
niitt from the S
Siitte
e menu and choosing C
Ca
alliib
brra
attiio
on
n.
3. Click on the metering channel you would like to calibrate, enter the correct metering value at the bottom
of the dialog box, and click C
Ca
alliib
brra
atte
e.
GSC3000 & VRC2500 INSTALLATION & OPERATION MANUAL
CHAPTER 4: I/O UNIT CONFIGURATION
42
Содержание GSC3000
Страница 8: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL viii ...
Страница 22: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 14 ...
Страница 32: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 24 ...
Страница 40: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 32 ...
Страница 52: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 44 ...
Страница 61: ...CHAPTER 6 MODEM SITE EQUIPMENT CONNECTIONS 53 CUSTOMER SUPPORT 978 486 3711 support burk com www burk com ...
Страница 68: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 60 ...
Страница 120: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 112 ...
Страница 128: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 120 ...
Страница 132: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 124 ...
Страница 140: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 132 ...
Страница 144: ...GSC3000 VRC2500 INSTALLATION OPERATION MANUAL 136 ...